EasyManuals Logo

Vivotek FD816B-H User Manual

Vivotek FD816B-H
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #257 background imageLoading...
Page #257 background image
VIVOTEK
User's Manual - 257
di 0,<positive integer> 6/6 Indicate the source id of di trigger.
This field is required when trigger condition is
“di”.
One bit represents one digital input. The LSB
indicates DI 0.
mdwin 0,<positive integer> 6/6 Indicate the source window id of motion
detection.
This field is required when trigger condition is
“md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows,
set mdwin as 5.
mdwin0 0,<positive integer> 6/6 Similar to mdwin. The parameter takes effect
when profile 1 of motion detection is enabled.
vi 0,<positive integer> 6/6 Indicate the source id of vi trigger.
This field is required when trigger condition is
“vi”.
One bit represents one digital input. The LSB
indicates VI 0.
vadp
<product dependent>
0,<positive integer> 6/6 Indicate the source id of vadp event notification.
Each bit corresponds to one vadp source, and
the LSB indicates source id 0.
For example, to detect event from any one of
source id 0, 1 and 3, set vadp to 11.
* Only available when vadp is listed in
"capability_supporttriggertypes"
valevel 0,1 6/6 Select audio detection event.
0: not select
1: select
valevel0 0,1 6/6 Select audio detection profile event.
0: not select
1: select
inter 1~999 6/6 Interval of snapshots in minutes.
This field is used when trigger condition is “seq”.

Table of Contents

Other manuals for Vivotek FD816B-H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vivotek FD816B-H and is the answer not in the manual?

Vivotek FD816B-H Specifications

General IconGeneral
BrandVivotek
ModelFD816B-H
CategorySecurity Camera
LanguageEnglish

Related product manuals