patrolseq string[64] 1/4 (For external device)
The indexes of patrol points, separated by “,”
patroldwelling string[128] 1/4 (For external device)
The dwelling time of each patrol point, separated by “,”
preset_i<0~(npre
set-1)>_name
string[40] 1/4 Name of the preset location.
preset_i<0~(npre
set-1)>_dwelling
0~999 1/4 The dwelling time of each preset location.
uart 0 ~ (m-1), m
is UART count
1/4 Select corresponding uart
(capability.nuart>0).
cameraid 0~255 1/4 Camera ID controlling external PTZ camera.
isptz 0 ~ 2 1/4 0: disable PTZ commands.
1: enable PTZ commands with PTZ driver.
2: enable PTZ commands with UART tunnel.
disablemdonptz <boolean> 1/4 Disable motion detection on PTZ operation.
Group: uart (capability.uart>0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~1
9,127>_name
string[40] 1/4 Name of the PTZ driver.
ptzdrivers_i<0~1
9,127>_location
string[128] 1/4 Full path of the PTZ driver.
enablehttptunnel <boolean> 4/4 Enable HTTP tunnel channel to control UART.
Group: uart_i<0~(n-1)> n is uart port count (capability.nuart>0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600
,1200,2400,
3600,4800,7
200,9600,19
200,38400,5
7600,115200
4/4 Set baud rate of COM port.
databit 5,6,7,8 4/4 Data bits in a character frame.
paritybit nne,odd,eve
n
4/4 For error checking.
stopbit 1,2 4/4 1,
2-1.5,data bit is 5