6 Stoelting
®
Mini Soft Serve Countertop Freezer Operator’s Manual
Reassemble the Machine and Lubricate Components
All parts should be cleaned, sanitized and allowed to air dry before
assembling.
NOTICE: Total Blend, Petrol-Gel or equivalent sanitary lubricant
must be used when lubrication of machine parts is
specified.
NOTICE: The United States Department of Agriculture and the Food
and Drug Administration require that lubricants used on
food processing equipment be certified for this use. Use
lubricants only in accordance with the manufacturer’s
instructions.
1. Turn off and unplug the machine.
2. Press the gear into bottom of the vertical auger and lubricate the
gear teeth with sanitary lubricant. Install the auger and secure it to
the machine with the fastening nut.
3. Press the gear onto the back of the horizontal auger. Lubricate the
gear teeth and the front of the auger with sanitary lubricant. Install
the auger.
4. Install the gasket into the bottom groove on the clear bowl. Make
sure the joint of the gasket is placed on one of the rear corners of the
clear bowl.
5. Install the clear bowl onto the machine and secure it with the
clamps. Screw the fastening knobs into the clamps.
6. Install the rosette cap.
7. Install the O-rings onto the spigot assembly and apply a thin film of
sanitary lubricant to the O-rings.
8. Install the spigot handle onto the fastening knobs.
9. Install the spigot assembly.
10.Secure the pivot arms to the spigot to the handle knobs.
NOTICE: Assemble both pivot arms onto the handle knobs at the
same time to prevent the arms from twisting and
breaking.
ADVANCED SETTINGS
Lock the Control Panel
The control panel can be locked to prevent accidental or unauthorized
changes to the machine settings.
1. Press .
2. Press or to navigate to KEYBOARD.
3. Press to select.
4. Press or to select KEYBOARD DISABLE.
5. Press to lock the control panel.
6. Press to exit the settings screens.
7. A triangle in the upper right corner of the display indicates the
control panel is locked. It will remain locked until the machine is
turned off.
Set Automatic Night Mode
Night Mode holds the mix in the machine at a food safe temperature
(approximately 28º F (-2.2º C)) during non-serving times. Automatic
Night Mode will override any manual settings. Therefore, set automatic
Night Mode only if you want the machine to enter and exit Night Mode
at the same times every day.
NOTICE: Night Mode does not take the place of cleaning and
sanitizing.
1. Press or to navigate to NIGHT.
2. Press to select NIGHT.
3. Press to ON to set the hour the machine should enter Night
Mode.
4. Press to move the cursor between ON and OFF, and the hour
and minutes for ON and OFF.
5. Press to save the settings.
MAINTENANCE
Monthly
Clean the Filter
NOTICE: Keep the filter clean. A dirty filter will impair refrigeration.
1. Turn off and unplug the machine.
2. Remove the filter. The filter is the back panel of the machine. Press
the tabs down to remove the filter.
3. Remove any large particles trapped behind the filter.
4. Wash the filter in warm, soapy water.
5. Rinse the filter with clean water.
6. Dry the filter and install it on to the machine.