12. SPECIFICATIONS
Display ..........................................LCD, 4000 counts with bargraph
Measuring rate ..............................approx. 2.5 measuring operations/second
Measuring line length ...................2 x approx. 120 cm (test prods), 1 x approx. 90 cm (alligator clip)
Measuring impedance ..................>10MΩ (V range)
Automatic power-off ......................approx. 10 minutes
Power supply ................................ 6 x AA batteries
Operating conditions .....................0 to 40 °C (< 80 % RH)
Operating altitude .........................max. 2,000 m
Storage temperature .....................-10 °C to +60 °C (< 70 % RH)
Weight ..........................................approx. 585 g
Dimensions (L x W x H) ................200 x 92 x 50 (mm)
Measuring category ...................... CAT III 1000 V
Degree of pollution .......................2
Measurement tolerances
Accuracy in ± (% of reading + display error in counts (= number of smallest points)). The accuracy is valid for one
year at a temperature of +23 °C (± 5 °C) with relative humidity less than 80 % RH, non-condensing.
Direct voltage
Range Resolution Accuracy
1000 V 1 V ±(0,8% + 3)
Overload protection: 1000 V; impedance approx.10 MOhm
Alternating voltage
Range Resolution Accuracy
750 V 1 V ±(1,2% + 10)
Frequency range 40 - 400 Hz; effective average at sinusoidal voltage; overload protection 750 V;
impedance approx. 10 MOhm
Resistance
Range Resolution Accuracy
40 Ω 0.01 Ω
±(1.2% + 3)
400 Ω 0.1 Ω
Overload protection 1000 V, test voltage max. 5.8 V, test current approx. 200 mA;
max. number of measurements with full batteries: x 500