1 Open the locking hooks for the housing lid (1)
and remove filter from the housing.
2 Bang the filter several times with the front face
vertically against the palm of your hand or
against a flat and soft surface.
3 Blow the filter out with dry compressed air
(pressure not higher than 5 bar (75.5 psi)) from
inside under an oblique angle, until the out
flowing air is free of dust.
4 Then inspect the filter with a lamp from inside to
outside for possible cracks.
NOTE!
Use only genuine filters. Non-genuine filters do not
fit and cause danger to the engine!
NOTE!
Operating the machine without air filter can lead to
major damage. Make sure an air filter is always
fitted!
Air filter, replacing
Replace the primary filter once a year or earlier if
clogging signal goes on.
1 Open the locking hooks for the housing lid and
remove filter (3).
2 Replace the filter and close the housing lid with
the locking hooks.
Take care of filters/oils/liquids in an environmentally
safe way, see page
137
.
2
1
V1196601
1 Housing lid
2 Dust valve
3
4
V1087184
3 Primary filter
164
Maintenance
Maintenance service, every 500 hours

Table of Contents