Page 3 ZC-KI6-VSS1707
CHECKLIST FOR THE INSTALLER
A Quick Check List
Are the water connections to the water heater oriented in a way to avoid
trapping air in the heating circuit? (see diagram on next page)
Is the purge valve installed on the return water line from the air handler
upstream from the isolation valve?
Is the air handler hung and isolated to avoid transmitting vibration through
framing and duct work?
Are the isolation valves full-port? Restrictive valves will limit performance.
Is outdoor cooling unit contactor wired according to the wiring diagram?
Are Thermostat connections correct, including cooling and continuous run
connections? Do they operate their intended zone?
Have the packing materials been removed from the blower?
Is there an installation manual and controls user manual for the home owner ?
Is the unit accessible? Are there clearances for service and component
replacement?
Is the return duct/drop acoustically lined ? (recommend lining at least 6 ft. of
the return duct/drop)
Is the filter cover in place? Is a clean filter in place?
Has the electronic controller been properly configured as per instructions in the
controls user manual?