EasyManua.ls Logo

W'eau WFI-013 - Running Parameter Checking

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 16 -
A
Fan Speed : Signal of Water pump : Wi-Fi function
Attention: With the indication of the functions or key parts, it is helpful for service
team to maintain or repair the heat pump.
6.9 Manual defrosting
Hold and for 3 seconds to start Manual defrosting function.
6.10 Factory setting recovery
Hold and and and for 5 seconds to recover factory setting.
6.11 Running Parameter checking
Press to enter the Running parameters checking, then press and to check the
below parameters as below:
N
°
Description
Unit
C01
Ambient temperature
°C
C02
Evaporator coil temperature
°
C
C03
Exhaust temperature
°C
C04
Return temperature
°
C
C05
Reserved
°C

Related product manuals