Why is my W'eau WMP-003 not running?
- DDeborah PalmerAug 2, 2025
If your W'eau Heat Pump isn't running, the first thing to check is the power supply. Make sure the cable is properly connected and the circuit breaker is on.
Why is my W'eau WMP-003 not running?
If your W'eau Heat Pump isn't running, the first thing to check is the power supply. Make sure the cable is properly connected and the circuit breaker is on.
What to do if W'eau WMP-003 is running short cycles?
If the W'eau Heat Pump is running for short periods, there could be several causes: 1. The fan might not be running. Check the cable connections between the motor and fan; replace if necessary. 2. Air ventilation might be insufficient. Ensure there are no obstacles blocking air ventilation around the heat pump unit. 3. There might not be enough refrigerant. In this case replace or repair the heat pump unit.
What to do if W'eau WMP-003 shows a water flow failure?
If the W'eau Heat Pump displays a water flow failure, check the water pump and piping system for any issues that might be causing insufficient or no water flow. Also, ensure the wiring for the water flow switch is securely connected. If not, check the wiring or replace the water flow switch.
How to fix water temperature sensor failure in W'eau Heat Pump?
If the W'eau Heat Pump indicates a water temperature sensor failure, start by checking the sensor wiring for any open or short circuits. If the wiring is intact, consider replacing the water temperature sensor.
How to troubleshoot piping temperature sensor failure on W'eau WMP-003 Heat Pump?
If the W'eau Heat Pump displays a piping temperature sensor failure, check the sensor wiring for any open or short circuits. If the wiring seems fine, replace the piping temperature sensor.
What to do if W'eau Heat Pump shows ambient temperature protection error?
If the W'eau Heat Pump is showing a 'too low or too high ambient temperature protection' error, this could be due to the ambient temperature being outside the operating range of 11°C - 42°C, or a controller failure. You should wait for the ambient temperature to rise to 13°C or cool down to 40°C to restart. If the problem persists, replace the controller.
What causes water stains on my W'eau Heat Pump?
If you notice water stains around your W'eau Heat Pump, this could be due to concreting or water leakage. Check the titanium heat exchanger carefully for any defects.
Warns about risks from leaking refrigerant in the heat exchanger and provides safety precautions.
Details hazards from faulty electrical installation or high mains voltage and requires authorized technicians.
Manufacturer disclaims responsibility for damage due to installation errors or non-conformity.
Provides detailed technical specifications for pool heat pump models.
Specifies requirements for placing the heat pump unit for optimal operation.
Details the steps for starting the heat pump after installation and connection.
Guides on safely connecting the heat pump to the power supply.
Explains the phenomenon of condensation on the evaporator fins during operation.
Illustrates the electrical connections for the heat pump models.
Describes the display and buttons of the LED wire controller.
Instructions on how to power the heat pump on and off using the controller.
Guides on adjusting the target water temperature for the heat pump.
Explains how to check and modify operational parameters.
Details the procedure to reset the controller to factory defaults.
Lists error codes, reasons, and solutions for controller display issues.
Addresses issues not shown on the LED controller, like no display or short running.