- 9 -
Press or directly to adjust the desired water temperature (parameter d, range:.15—40 ), the
data will be saved in 3 seconds.
Or you can adjust the Parameter d to set your desired water temperature.
5.4 Parameter checking& adjusting
Hold button for 5 seconds, it will enter the parameter checking, Press or to check the below
parameters.
Then press again to enter the current parameter adjusting, press or to make the adjustment,
then press to save the setting.
Parameter
Description
Range
Default
Remark
A
Inlet water temp.
-19
99
Real data
b
Piping temp.
-19
99
Real data
C
Ambient temp.
-19
99
Real data
d
Desired water temp.
15
℃~
40
27
Adjustable
H
Return water temp. difference
1
℃~
10
2
Adjustable
J
Power-fail protection
0
1
1 (Yes)
Adjustable
O
The lowest ambient temp. for running
0
℃~
15
11
Unadjustable
5.5 Restroe factory setting
Hold and for 10 seconds to restore the factory settings.
NOTE: the heat pump can run only if the water circle/filtration system is running.
NOTE: The other parameters which is not shown on below sheet is for reservation, no real function.