EasyManua.ls Logo

W'eau WMIP-003 - User Manual

W'eau WMIP-003
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation & Operation Manual
Mini Inverter Plus Heat Pump
Model: WMIP-003/004/006
ENGLISH/ DUTCH
Thank you very much for purchasing our product,please keep and read this manual carefully before
you install heat pump.

Questions and Answers

  • J
    Jeffrey CarrAug 19, 2025
    What to do if my W'eau Heat Pump LED wire controller has no display and the heat pump isn't running?
    • I
      Ian GillespieAug 19, 2025
      If there is no display on the LED wire controller and the W'eau Heat Pump is not running, the cause may be no power supply. Check the cable and circuit breaker to ensure they are properly connected.
  • M
    Melissa MuellerAug 21, 2025
    What does error code E03 mean on my W'eau WMIP-003 Heat Pump?
    • D
      David SuarezAug 21, 2025
      Error code E03 on your W'eau Heat Pump indicates insufficient or no water flow, or a loose wiring situation for the water flow switch. Check the water pump and piping system. Also, check the wiring or replace the water flow switch.
  • P
    Peter Scott DDSAug 23, 2025
    What does error code E09 mean on my W'eau Heat Pump?
    • A
      Alexis JordanAug 23, 2025
      Error code E09 on your W'eau Heat Pump suggests a bad connection or a broken controller/PCB. First, check the wiring between the PCB and the controller. If the problem persists, replace the controller or PCB.
  • M
    Manuel HughesAug 26, 2025
    What does error code E10 mean on my W'eau WMIP-003 Heat Pump?
    • E
      Elizabeth PotterAug 26, 2025
      Error code E10 on your W'eau Heat Pump indicates a bad connection or a broken controller/PCB. Check the wiring between the driver board and the controller. If the issue continues, replace the controller or driver board.
  • D
    David RollinsAug 28, 2025
    What to do if my W'eau WMIP-003 Heat Pump LED wire controller displays the actual water temperature?
    • W
      williamfriedmanAug 28, 2025
      If the LED wire controller displays the actual water temperature, it could mean that the water temperature is reaching the setting value, indicating the heat pump is under constant temperature status. Alternatively, the heat pump might have just started running. Verify the water temperature setting. If the heat pump has just started, allow it to run for a few minutes.
  • D
    David FuentesAug 29, 2025
    What does error code E46 mean on my W'eau WMIP-003?
    • J
      Jennifer Newman MDAug 30, 2025
      Error code E46 on your W'eau Heat Pump indicates a bad connection or a broken fan motor. Check the wiring of the fan motor. If necessary, replace the fan motor.
  • E
    Emily BarnesSep 1, 2025
    What does error code E15 mean on my W'eau Heat Pump?
    • J
      Johnny WatsonSep 1, 2025
      Error code E15 on your W'eau Heat Pump indicates a temperature sensor open circuit or short circuit. Check the sensor wiring. If the problem persists, replace the temperature sensor.
  • G
    Gerald MckeeSep 3, 2025
    What does error code E16 mean on my W'eau WMIP-003?
    • D
      davidwalkerSep 3, 2025
      Error code E16 on your W'eau Heat Pump suggests a temperature sensor open circuit or short circuit. First, check the sensor wiring. If the problem persists, replace the temperature sensor.
  • H
    hannah15Sep 5, 2025
    What does error code E18 mean on my W'eau WMIP-003?
    • W
      William ForbesSep 5, 2025
      Error code E18 on your W'eau Heat Pump indicates a temperature sensor open circuit or short circuit. Check the sensor wiring. If the problem continues, replace the temperature sensor.
  • T
    Tammy Patterson DVMSep 7, 2025
    Why does my W'eau WMIP-003 Heat Pump show error code E04?
    • S
      Steven HillSep 7, 2025
      Error code E04 on your W'eau Heat Pump is a protection for the system due to low ambient temperature.

Summary

Specifications

Technical Data

Provides detailed technical specifications for different pool heat pump models.

Dimensions

Installation and Connection

Heat Pump Location

Details optimal placement criteria for the heat pump unit.

Initial Operation

Explains the initial steps before starting the heat pump operation.

Electrical Connection

Guides users on how to properly connect the heat pump electrically.

Condensation Handling

Explains the phenomenon of condensation and how to drain it.

Electrical Wiring

Wiring Diagram

Illustrates the internal wiring connections for the pool heat pump.

Controller Operation

LED Controller Interface

Describes the visual elements and indicators on the LED controller.

Powering On;Off

Provides instructions for powering the heat pump on and off.

Switching Heating;Cooling Modes

Explains how to change between heating and cooling operational modes.

Setting Water Temperature

Guides users on setting the target water temperature.

Real Data Checking

Details how to view operational parameters and sensor readings.

Parameter Checking

Lists and explains various adjustable parameters and their ranges.

Manual Defrosting

Instructions on how to manually initiate the defrosting cycle.

Factory Setting Recovery

Steps to restore the heat pump to its original factory default settings.

Troubleshooting

Error Codes

Lists error codes, their reasons, and corresponding solutions.

Other Malfunctions

Addresses malfunctions not indicated by specific error codes on the controller.

Maintenance

WiFi Function

W'eau WMIP-003 Specifications

General IconGeneral
BrandW'eau
ModelWMIP-003
CategoryHeat Pump
LanguageEnglish

Related product manuals