Installation & Operation Manual
Mini Inverter Plus Heat Pump
Model: WMIP-003/004/006
ENGLISH/ DUTCH
Thank you very much for purchasing our product,please keep and read this manual carefully before
you install heat pump.

Questions and Answers

  • P
    Peter ReyesSep 10, 2025
    What does error code E21 mean on my W'eau WMIP-003 Heat Pump?
    • J
      James JohnsonSep 10, 2025
      Error code E21 on your W'eau Heat Pump indicates a temperature sensor open circuit or short circuit. Check the sensor wiring. If the problem persists, replace the temperature sensor.
  • S
    Shannon KerrSep 12, 2025
    What to do if my W'eau Heat Pump LED wire controller is short running?
    • C
      Carolyn ParsonsSep 12, 2025
      If your W'eau Heat Pump LED wire controller is short running, it could be due to several reasons: 1. The fan is not running. 2. Insufficient air ventilation. 3. Insufficient refrigerant. Check the cable connections between the motor and fan, and replace if necessary. Ensure the heat pump unit has good air ventilation by removing any obstacles. If the issue persists, replace or repair the heat pump unit.
  • C
    Christopher JohnsonSep 13, 2025
    What does error code E12 mean on my W'eau WMIP-003?
    • D
      Devin ThomasSep 14, 2025
      Error code E12 on your W'eau Heat Pump indicates insufficient gas in the system. Check for gas leakage in the piping system.
  • C
    Courtney HardySep 16, 2025
    What to do if my W'eau WMIP-003 LED wire controller has water stains?
    • D
      Dawn GregorySep 16, 2025
      If your W'eau Heat Pump LED wire controller has water stains, it could be due to concreting or water leakage. For water leakage, carefully check the titanium heat exchanger for any defects.

Summary

Specifications

Technical Data

Provides detailed technical specifications for different pool heat pump models.

Dimensions

Installation and Connection

Heat Pump Location

Details optimal placement criteria for the heat pump unit.

Initial Operation

Explains the initial steps before starting the heat pump operation.

Electrical Connection

Guides users on how to properly connect the heat pump electrically.

Condensation Handling

Explains the phenomenon of condensation and how to drain it.

Electrical Wiring

Wiring Diagram

Illustrates the internal wiring connections for the pool heat pump.

Controller Operation

LED Controller Interface

Describes the visual elements and indicators on the LED controller.

Powering On;Off

Provides instructions for powering the heat pump on and off.

Switching Heating;Cooling Modes

Explains how to change between heating and cooling operational modes.

Setting Water Temperature

Guides users on setting the target water temperature.

Real Data Checking

Details how to view operational parameters and sensor readings.

Parameter Checking

Lists and explains various adjustable parameters and their ranges.

Manual Defrosting

Instructions on how to manually initiate the defrosting cycle.

Factory Setting Recovery

Steps to restore the heat pump to its original factory default settings.

Troubleshooting

Error Codes

Lists error codes, their reasons, and corresponding solutions.

Other Malfunctions

Addresses malfunctions not indicated by specific error codes on the controller.

Maintenance

WiFi Function

W'eau WMIP-003 Specifications

General IconGeneral
BrandW'eau
ModelWMIP-003
CategoryHeat Pump
LanguageEnglish