6 Appendix III — Special Applications
41
Meritor WABCO Maintenance Manual 34 (Revised 03-16)
Combo Tank Installation for Regeneration-Style Air Dryers
Figure 6.7
Figure 6.7
PURGE
VALVE
(EXHAUST)
COMPRESSOR
DISCHARGE
LINE
COMPRESSOR
COMPRESSOR
INTAKE LINE
PRESSURE-
CONTROLLED
CHECK VALVE
*
SUPPLY
TANK
(WET)
SYSTEM
RESERVOIR
INTERNAL
CHECK
VALVE
DRYER
INLET
PORT
UNLOADER
LINE
RESERVOIR-
TO-GOVERNOR
LINE
1800
1200
SYSTEM
RESERVOIR
CHECK
VALVE
SUPPLY
LINE
DRYER
OUTLET
PORT
REGENERATION
VALVE
GOVERNOR
*
ALTERNATE PCCV LOCATION
WITH COMBO RESERVOIR
CONTROL
(PURGE) PORT
SYSTEM SAVER SERIES
REGENERATION
STYLE AIR DRYER
UNLOADER
PORT
4003883a