Service Manual
09/30/10 32DSKE02.B.1 ©2010 RICON CORPORATION
All Rights Reserved
U.S. Patent Nos: 4,534,450; 5,228,538; 5,308,215; 5,373,915; 5,445,488; 5,605,431; 5,944,473; 6,043,741
Australia Patent Nos: 661127; 697066
Canadian Patent Nos: 1,245,603; 2,129,821; 2,168,761
German and U.K. EP0625896B1
Other U.S. and foreign patents pending
®
S-SERIES
AND K-SERIES
EXPORT USE WHEELCHAIR
AND STANDEE LIFT
S-Series K-Series
TM
TM
-
Prin
t
-
-
Hom
e
-

Questions and Answers

  • A
    Ashley SalazarAug 10, 2025
    What to do if my Wabtec Ricon K1200 Lifting Systems lift functions with abnormal operation?
    • C
      Christina JohnsonAug 10, 2025
      If your Wabtec Lifting Systems lift is operating abnormally, first check for any obstructions in the lifting frame and remove them, inspecting for damage. Ensure the backup pump manual release valve is turned clockwise until slightly snug. Also, check that the hydraulic fluid level is at the required FULL level while the platform is at ground level, adding Texaco 01554 Aircraft Hydraulic Oil or equivalent U.S. mil spec H5606G fluid if needed. Finally, purge the hydraulic system by operating the lift through its maximum range of travel for at least four complete cycles. If the vehicle doesn't use the full travel of the lift, raise the vehicle on a service hoist or ramp to accomplish the maximum range of travel.
  • J
    Justin SantiagoAug 17, 2025
    Why is my Wabtec Lifting Systems lift not working?
    • T
      Tracy BurnsAug 18, 2025
      If your Wabtec Lifting Systems lift is not operating, start by resetting the control system circuit breaker. Ensure the backup pump manual release valve is turned clockwise until slightly snug. Check that the hydraulic fluid level is at the required FULL level while the platform is at ground level, adding Texaco 01554 Aircraft Hydraulic Oil or equivalent U.S. mil spec H5606G fluid if needed. Purge the hydraulic system by operating the lift through its maximum range of travel for at least four complete cycles. (For vehicles that do not use full travel of lift, the maximum range of travel is accomplished by raising vehicle on a service hoist or ramp.) For hydraulic hose or fitting leaks, contact an authorized Vapor Ricon dealer for repair.
  • D
    Debra EstesAug 26, 2025
    How to fix hydraulic fluid leaks in Wabtec Ricon K1200?
    • S
      Stefanie HensleyAug 26, 2025
      If you notice hydraulic fluid leaks in your Wabtec Lifting Systems, first ensure that all hydraulic fittings are properly tightened. If the leak persists, discontinue use of the lift and have repairs made by an authorized Vapor Ricon dealer, as a hydraulic component may be defective.
  • D
    Daniel WhiteSep 2, 2025
    What to do if the rollstop doesn't open on my Wabtec Ricon K1200?
    • T
      Timothy DickersonSep 2, 2025
      If the rollstop on your Wabtec Lifting Systems does not open, raise the lift and check for any obstruction of the rollstop release latch. Remove any obstruction that you find.

Summary

INTRODUCTION

RICON PRODUCT WARRANTY

Details the five-year limited warranty terms, coverage, and exclusions.

GENERAL SAFETY PRECAUTIONS

Essential safety guidelines for installation, operation, and maintenance.

INSTALLATION

MECHANICAL INSTALLATION

Procedures for positioning and mounting the lift assembly in the vehicle.

ELECTRICAL INSTALLATION

Steps for connecting the lift's power supply, breakers, and control systems.

FINAL ADJUSTMENTS

Calibration procedures for limit switches, platform tilt, and linkages.

MAINTENANCE AND REPAIR

TROUBLESHOOTING

Guides for diagnosing and resolving common lift operational problems.