11 Maintenance
43
Topping up with fuel
1. Remove any dirt around the fuel cap.
2. Slowly unscrew and remove fuel cap.
Note: Slowly unscrew the fuel cap so that any overpressure can slowly escape.
3. Use a clean funnel to replenish fuel.
See chapter Technical data for the fuel specification.
See chapter Technical data for the fuel mixing table.
4. Position the fuel cap and tighten it.
11.3.3 Checking/cleaning air cleaner
Performing preparations
1. Switch off the engine.
2. Lean the machine upright against a solid object and secure it to prevent it
from toppling over.
Wacker Neuson recommends to hang the machine on the truck.
3. Let machine cool off.
Removing the air cleaner cartridge
1. Remove any dirt around the air cleaner cap.
2. Unscrew and remove all nuts of the air cleaner cap with a screw wrench.
3. Remove the air cleaner cap.
4. Remove air cleaner cartridge.
Checking/cleaning air cleaner cartridge
f Tap out air cleaner cartridge and blow out from inside to outside with com-
pressed air.
Note: When tapping, make sure that the air cleaner cartridge is not damaged.
If the dust can no longer be removed, change the air cleaner cartridge.
www.JACKHAMMERS.com
MATW, INC.
800-241-9669

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson BH 23 and is the answer not in the manual?

Wacker Neuson BH 23 Specifications

General IconGeneral
BrandWacker Neuson
ModelBH 23
CategoryPower Hammer
LanguageEnglish

Related product manuals