BA D18 us* 1.1 * D18w700.fm 7-7
Maintenance 7
Other maintenance intervals (Wacker Neuson service center):
• Every 500 operating hours or annually
• Every 1000 operating hours
• Every 1500 operating hours
• Every 2000 operating hours
• Every 3000 operating hours
Maintenance with the note Wacker Neuson service center must be
performed only by the trained and qualified personnel of a Wacker
Neuson service center.
Weekly maintenance (every 50 operating hours) (operator) Page
All steps for previous maintenance intervals --
Lubricate the machine according to the lubrication plan 7-9, 7-19
Check the axle mounting for tightness (visual check) --
Check the wheel nuts for tightness (visual check) 7-40
Check accesses and exits for dirt --
Replace the air filter
1
1. Air filter replacement according to the indicator light, every 1000 o/h or once a year at the latest. (Replace after 50 o/h when in extensive use in environments
with acidic air, such as acid production facilities, steel and aluminum mills, chemical plants and other nonferrous-metal plants, independently of the indicator
light. Contact a Wacker Neuson service center.)
7-32
Only once after the first 50 operating hours (Wacker Neuson service center) Page
Replace the oil filter of the machine-travel hydraulics --
Replace the oil filter of the operating hydraulics --
Replace the gearbox oil in the traveling drive, axles and transfer gearbox --
Check V-belt condition and tension (Tier III only) --
Check the threaded fittings for tightness --
Check labels and Operator’s Manual for completeness and condition --
Check the pressure of the primary pressure limiting valves --
Retighten the axle mounting --
Retighten the wheel nuts --
Reset the maintenance meter --
All steps for maintenance once a day and once a week --