BA D18 us* 1.1 * D18i400.fm 4-35
Putting into operation 4
Starter
Starting the engine
1. Switch off all electric consumers.
2. Insert the starting key.
3. Turn the starting key to position 1.
4. All indicator lights illuminate for two seconds.
➥ Have malfunctioning indicator lights immediately replaced.
5. Turn and hold the starting key in position 2 until indicator light A
(preheating) goes out.
➥ Indicator light B (alternator charge) illuminates.
➥ Indicator light C (engine oil pressure) illuminates.
6. Turn and hold the starting key in position 3 until the engine starts.
➥ Release the starting key.
➥ All indicator lights go out.
If the engine does not start after 30 seconds:
Interrupt the start procedure and repeat it after two minutes.
If the engine still does not start after a few tries, contact a Wacker Neuson
service center.
Warm-up phase
After starting the engine, let it warm up at slightly increased idling speed
until it reaches its operating temperature.
Check for unusual noise, exhaust color, leaks, malfunctions or damage.
In case of malfunctions, damage or leaks:
Secure the machine, park it and find out the cause for the damage and
have it repaired.
Position Function
P Park position
Insert or remove the starting key
0 Stop position
1 Position for accessories All electric functions are enabled
2 Preheats the engine Preheater active
3 Starts the engine Starter is actuated