BA D18 us* 1.1 * D18w700.fm 7-23
Maintenance 7
Tier IV
1. Stop and park the machine. Stop the engine – see “Preparing
lubrication” on page 7-8.
2. Open the maintenance flap on the right.
3. Unlock tank lock A with the starting key.
4. Open tank lock A carefully to release the pressure in the fuel tank.
5. Refuel.
6. Close and lock filler cap.
7. Press pump A several times until a firmer resistance can be felt.
8. Press pump A 5 x.
9. Close and lock the maintenance flap on the right.
10.Start the engine.
If the engine runs smoothly for a while and then dies, or if it does not run
smoothly:
1. Stop the engine.
2. Remove the starting key and carry it with you.
3. Bleed the fuel system again as described above.
4. Check for leaks after starting the engine.
5. Have a Wacker Neuson service center perform a check if necessary.
The fuel system can also be bled if the engine is warm.
Water separator
The water separator is located behind the maintenance flap on the right in
the engine compartment.
A water/fuel mixture is collected in the water separator during operation.