Loading...
BA D18 us* 1.1 * D18w700.fm 7-29
Maintenance 7
Checking the coolant level
1. Stop and park the machine. Stop the engine see Preparing
lubrication” on page 7-8.
2. Let the engine and the coolant cool down.
3. Open the maintenance flap on the left.
4. Check the coolant level on sight glass A.
If the coolant level is below the FULL mark:
Add coolant.
5. Close and lock the maintenance flap on the left.
Information
Check the coolant level once a day before starting the engine.
Observe the coolant compound table.
Adding coolant
1. Stop and park the machine. Stop the engine see Preparing
lubrication” on page 7-8.
2. Let the engine and the coolant cool down.
3. Open the maintenance flap on the left.
4. Carefully unscrew filler cap B and release the pressure.
5. Open filler cap B.
6. Add coolant up to the FULL mark.
7. Close filler cap B.
8. Start the engine and let it warm up for about 5 – 10 minutes.
9. Stop the engine.
10.Check the coolant level again on the sight glass.
11.If necessary, add coolant and repeat the procedure until the coolant
level remains constant.
12.Close and lock the maintenance flap on the left.
Fig. 188
A
B
FULL