BA D18 us* 1.1 * D18w710.fm 7-47
Maintenance 7
Automatic regeneration mode
The automatic regeneration mode is preset if the engine is stopped for
at least 30 seconds.
NOTICE
Fire hazard at the exhaust system.
There must be no easily flammable material in the direct vicinity of the
muffler, in particular near the end pipe.
In environments with easily flammable material, disable the automatic
regeneration mode.
If the particulate matter catalyst has reached a certain contamination level,
indicator light B illuminates and an automatic regeneration is performed soon.
Indicator light C illuminates in addition during regeneration.
Information
The machine can be operated as usual during regeneration.
Disabling/interrupting the automatic regeneration mode:
Press and hold push button A at least 3 seconds in position 1.
Indicator light D illuminates.
To re-enable the automatic regeneration mode:
Press and hold push button A at least 3 seconds in position 1.
Indicator light D goes out.
Information
Disabling regeneration increases the contamination level in the particulate filter.
Fig. 206Fig. 206
1
A
Fig. 207
B C D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DW90 and is the answer not in the manual?

Wacker Neuson DW90 Specifications

General IconGeneral
BrandWacker Neuson
ModelDW90
CategoryExcavators
LanguageEnglish

Related product manuals