BA EZ17 en* 1.1 * ez17e300.fm 3-3
Introduction 3
Canopy
The canopy has been specially designed for protection in case of an
accident.
• ROPS/TOPS tested canopy.
• Protective FOPS structure level I (option); Protective structure against
falling objects.
• Shatter protection (option); Protective structure against frontal flying
fragments.
The machine is not available with a closed cab.
A restricted work range applies to work with attachments (for example
breaker) that can cause fragments to fly around – see chapter “ Shatter
protection (option)” on page 4-14, figure Fig. 60.
Installing a protective Front Guard structure according to EN 474-5 (item
5.3.2.1) is not possible. Only perform work that does not require a
protective Front Guard structure.
Definition of FOPS/Front Guard levels
Level I:
Protection against small falling objects (FOPS) or small objects
penetrating into the cabin from the front (Front Guard), such as bricks,
small pieces of concrete, tools, for machines that are used for repairing
roads, landscaping work and for working on other construction sites, for
example.
Level II:
Protection against heavy falling objects (FOPS) or heavy objects
penetrating into the cabin from the front (Front Guard), such as trees,
pieces of rock, for machines that are used for clearance work, demolition
work and forestry work, for example.
Upper carriage
EZ: Zero tail revolving superstructure; the revolving superstructure does
not project over the width of the vehicle with an extended telescopic travel
gear without a rear weight when rotating.
Fig. 3 (symbolic
representation)