Maintenance GP/GPS 5600A
42 wc_tx000797gb.fm
4.6 Cleaning the Sediment Cup
4.6.1 Turn the fuel valve off.
4.6.2 Remove the sediment cup (a) and the O-ring (b).
4.6.3 Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
4.6.4 Turn the fuel valve on and check for leaks.
4.7 Engine Speed
Generators require a fixed engine speed to maintain the correct
voltage. Engine speed is controlled by a governor which automatically
adjusts to varying loads on the engine to maintain a constant speed.
There is no throttle control.
To set the engine to the proper speed:
Turn the speed adjusting screw (b) in or out to obtain a no-load speed.
See Technical Data.
NOTICE: Setting the engine speed too high or too low may damage
tools and other appliances attached to the generator.