EasyManuals Logo

Wacker Neuson GP 5600A User Manual

Wacker Neuson GP 5600A
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Maintenance GP/GPS 5600A
42 wc_tx000797gb.fm
4.6 Cleaning the Sediment Cup
4.6.1 Turn the fuel valve off.
4.6.2 Remove the sediment cup (a) and the O-ring (b).
4.6.3 Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
4.6.4 Turn the fuel valve on and check for leaks.
4.7 Engine Speed
Generators require a fixed engine speed to maintain the correct
voltage. Engine speed is controlled by a governor which automatically
adjusts to varying loads on the engine to maintain a constant speed.
There is no throttle control.
To set the engine to the proper speed:
Turn the speed adjusting screw (b) in or out to obtain a no-load speed.
See Technical Data.
NOTICE: Setting the engine speed too high or too low may damage
tools and other appliances attached to the generator.

Table of Contents

Other manuals for Wacker Neuson GP 5600A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson GP 5600A and is the answer not in the manual?

Wacker Neuson GP 5600A Specifications

General IconGeneral
BrandWacker Neuson
ModelGP 5600A
CategoryPortable Generator
LanguageEnglish

Related product manuals