PS (3-Phase) Series Maintenance
wc_tx000132gb.fm 35
The pump's head and pump-
ing volume is decreased.
The impeller is worn. Replace.
The hose may be kinked or clogged. Minimize the
number of bends in the hose. (In an area with a large
amount of debris, use the pump in a meshed enclo-
sure.)
The strainer is obstructed or buried. Remove the
obstruction. Place a concrete block under the pump
to prevent the pump from picking up debris.
The motor rotates in reverse. Interchange the power
supply terminal leads.
The pump generates noise or
vibration.
The bearing of the motor may be damaged. To
replace the bearing, contact the dealer from whom
you purchased the equipment, or the Wacker sales
office in your area.