EasyManuals Logo

Wacker Neuson WM 170 User Manual

Wacker Neuson WM 170
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Maintenance WM 130/170/270
wc_tx000242gb.fm 24
6. Maintenance
6.1 Periodic Maintenance Schedule
Maintenance, replacement or repair of emission control devices and systems may be performed by any
repair establishment or individual.
Daily
before
starting
After
first 20
hours
Every
2 weeks
or
50 hrs.
Every
month
or
100 hrs.
Every
year
or
300 hrs.
Every
500 hrs.
Check fuel level.
Check engine oil level.
Inspect fuel lines.
Inspect air filter. Replace as
needed.
Check and tighten external
hardware.
Clean air cleaner elements.
Change engine oil.
••
Clean sediment cup / fuel filter.
Check and clean spark plug.
Check and adjust valve clear-
ance.
Replace spark plug.

Other manuals for Wacker Neuson WM 170

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson WM 170 and is the answer not in the manual?

Wacker Neuson WM 170 Specifications

General IconGeneral
BrandWacker Neuson
ModelWM 170
CategoryEngine
LanguageEnglish

Related product manuals