Maintenance WM 130/170/270
wc_tx000242gb.fm 28
6.6 Storage
If machine is being stored for more than 30 days:
6.6.1 Drain fuel from tank. Start engine and run until remaining fuel is used.
6.6.2 Remove spark plug. Pour approximately 5 cc of clean SAE 10W30
engine oil into cylinder through spark plug opening. Pull starter rope
slowly to distribute oil in engine. Reinstall spark plug.
6.6.3 Change oil.
6.6.4 Cover engine and store in a clean, dry area.