EasyManua.ls Logo

WACO 2609C - DC Voltage Specifications; AC Voltage (True RMS) Specifications

WACO 2609C
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC Volts
Range
660mV
6.6V
66V
660V
1000V
Resolution
0.1mV
1mV
10mV
100mV
1V
Accuracy
± (0.5% rdg + 2d)
± (0.5% rdg + 2d)
± (0.5% rdg + 2d)
± (0.5% rdg + 2d)
> 100M
10M
9.1M
9.1M
9.1M
Overload protection: 1000V DC or 750V AC rms
AC Volts (True RMS)
Range
660mV
6.6V
66V
660V
750V
Resolution
0.1mV
1mV
10mV
100mV
1V
Accuracy (50~500Hz)
± (1.5% rdg + 8d) 50~100Hz
± (1.5% rdg + 8d) 50~500Hz
± (1.5% rdg + 8d) 50~500Hz
± (1.5% rdg + 8d) 50~500Hz
± (1.5% rdg + 8d) 50~500Hz
Crest Factor: 3
AC coupled true rms specified from 5% to 100% of range
FREQUENCY Ranges: 50Hz ~ 1kHz.
Accuracy: ±(0.1% rdg + 5 dgts)
Minimum Input voltage Range: >500dgts.
The readings of frequency measurements will show on the sub-
display.
Overload protection: 1000V DC or 750V AC rms
12
Input Impedance
> 100M
10M
9.1M
9.1M
9.1M
Input Impedance
± (0.5% rdg + 2d)
2609C.p65 ?2009/12/15, 上午 09:1514