DC current
Range
Resolution
Accuracy
0~660A±(2.0% rdg+5d)
660~1000A±(3.0% rdg+5d)
1000~2000A±(5.0% rdg+5d)
660A
2000A
0.1A
1A
Overload protection: 2000A DC for 60 seconds maximum.
13
AC current (True RMS)
Range Resolution Accuracy (50 ~ 400Hz)
0~660A±(2.0% rdg+10d)50~60Hz
0~660A±(3.0% rdg+10d)61~400Hz
660~1000A±(2.5% rdg+10d)50~60Hz
660~1000A±(3.5% rdg+10d)61~400Hz
1000~1500A±(5.0% rdg+10d)50~400Hz
660A
1500A
0.1A
1A
Crest Factor: 3
AC coupled true rms specified from 5% to 100% of range
FREQUENCY Ranges: 50Hz ~ 1kHz.
Accuracy: ±(0.1% rdg + 5 dgts)
Minimum Input current Range: >500dgts.
The readings of frequency measurements will show on the sub-display.
Overload protection: 1500A AC.