Questions and Answers

  • A
    amendezJul 30, 2025
    Why does my Waeco Refrigerator compressor run continuously?
    • J
      John OconnorJul 30, 2025
      If your Waeco Refrigerator's compressor runs for a long time or continuously, it could be due to several reasons. The evaporator might be iced over, in which case you should defrost it. Check the cooling area insulation; if it's insufficient, moist, or wet, adjust or replace the door seal. Ensure sufficient ventilation and clean the condenser if it's dirty. If your refrigerator has a fan, a defective fan could also be the cause, so replace it if necessary.
  • J
    Justin RomanAug 3, 2025
    How to fix a Waeco CoolMatic RPD-175 that won't turn on?
    • R
      Robert AlvarezAug 3, 2025
      If the Waeco Refrigerator does not function and the power LED does not glow, it could be due to two primary reasons. First, there might be no voltage present in the 12/24 V supply. Check the power source to ensure the battery is switched on. Second, the integrated mains adapter might be defective, which requires repair by an authorized repair center.
  • C
    cpittmanAug 7, 2025
    What to do if my Waeco CoolMatic RPD-175 is not cooling?
    • T
      Tina FrankAug 7, 2025
      If your Waeco Refrigerator does not cool, even though power is present and the “POWER” LED is lit, it indicates a defective component. This issue can only be resolved by an authorized repair center.
  • D
    Dorothy MoralesAug 12, 2025
    Why is my Waeco CoolMatic RPD-175 having trouble starting?
    • W
      wendy65Aug 12, 2025
      There are several reasons why your Waeco Refrigerator might have trouble starting. First, insufficient ventilation could be the issue, so ensure you install sufficient ventilation. Second, a dirty condenser can cause starting problems, so clean it thoroughly. Lastly, a defective fan could be the culprit, requiring a replacement.
  • B
    Brad ClarkAug 16, 2025
    What to do if my Waeco CoolMatic RPD-175 Refrigerator compressor runs constantly?
    • J
      Jennifer BarnesAug 16, 2025
      If your Waeco Refrigerator's compressor runs constantly, it could be due to a couple of reasons. The thermostat sensor may not have contact with the evaporator; in this case, secure the sensor. Alternatively, there might be a short circuit in the thermostat line, or the thermostat itself could be defective, requiring you to change the thermostat.
  • E
    ekempAug 20, 2025
    Why doesn't my Waeco CoolMatic RPD-175 Refrigerator compressor run often?
    • C
      Christopher LiuAug 20, 2025
      If the compressor on your Waeco Refrigerator doesn't run often enough, it might be because the battery capacity is exhausted. In this case, you should charge the battery.
  • J
    John BondAug 25, 2025
    Why is my Waeco CoolMatic RPD-175 making a loud humming noise?
    • R
      Russell CastilloAug 26, 2025
      If your Waeco Refrigerator is making a loud humming noise, it could be due to a couple of reasons. A component of the refrigerant circuit might not be moving freely because it's against the wall; carefully bend the component. Alternatively, there could be a foreign body jammed between the cooling device and the wall, so remove the foreign body.

Summary

Safety Instructions

General Safety Precautions

General safety rules for refrigerator operation and installation.

Electrical Safety and Boat Usage

Safety for electrical connections and boat use.

Installing and Connecting the Refrigerator

Installation Safety for Boats

Safety guidelines for installing the refrigerator on boats.

Connecting to a Battery

Guide for connecting the refrigerator to a DC power source.

Using the Refrigerator

Cleaning and Maintenance

Troubleshooting

General Faults and Remedies

Common issues like no power or cooling with solutions.

Trouble Starting Issues

Problems with the device not starting or running.

Technical Data

Waeco CoolMatic RPD-175 Specifications

General IconGeneral
Capacity175 liters
Power Supply12/24 V DC
Power SourceBattery or mains
Cooling TechnologyCompressor
Weight39 kg
Energy Consumption0.6 kWh/24h
RefrigerantR134a
MaterialPlastic, Metal
ColourSilver
Current Consumption5A (12V), 2.5A (24V)