CoolMatic CD50, CRD50
DE 8 Kühlschrank
Montage- und Bedienungsanleitung
EN 29 Refrigerator
Installation and Operating Manual
FR 49 Réfrigérateur
Instructions de montage et de service
ES 73 Nevera
Instrucciones de montaje y de uso
IT 96 Frigorifero
Istruzioni di montaggio e d’uso
NL 119 Koelkast
Montagehandleiding en gebruiks-
aanwijzing
DA 140 Køleskab
Monterings- og betjeningsvejledning
SV 160 Kylskåp
Monterings- och bruksanvisning
NO 180 Kjøleskap
Monterings- og bruksanvisning
FI 200 Jääkaapp
Asennus- ja käyttöohje
PT 220 Frigorífico
Instruções de montagem e manual de
instruções
RU 242 Холодильник
Инструкция по монтажу и
эксплуатации
PL 266 Lodówka
Instrukcja montażu i obsługi
CS 289 Lednička
Návod k montáži a obsluze
SK 309 Chladnička
Návod na montáž a uvedenie do
prevádzky
HU 330 Hűtőszekrény
Szerelési és használati útmutató

Table of Contents

Other manuals for Waeco CoolMatic CD50

Questions and Answers

  • C
    Christina GordonAug 19, 2025
    How to fix a loud humming noise in my Waeco CoolMatic CD50?
    • C
      Calvin ValenciaAug 19, 2025
      Loud humming from your Waeco Refrigerator can be caused by a component of the refrigerant circuit touching the wall, preventing free movement. Carefully bend the component away from the obstruction. Alternatively, a foreign body might be jammed between the cooling unit and the wall; remove it to resolve the humming.
  • C
    cmatthewsAug 21, 2025
    Why Waeco CoolMatic CD50 shows 'U ? U Term ON'?
    • M
      Michele MooreAug 21, 2025
      The 'U ? U Term ON' error on your Waeco Refrigerator may be due to several reasons: the battery voltage is too low (charge the battery), loose cables or poor contact due to corrosion (establish a connection), the battery capacity is too low (replace the battery), or the cable cross section is too small (replace the cable).
  • L
    Lisa MurphyAug 23, 2025
    What to do if my Waeco CoolMatic CD50 displays 'U = 0 V Term'?
    • S
      Sarah LucasAug 23, 2025
      If your Waeco Refrigerator displays 'U = 0 V Term', it indicates a problem with the power supply. This could be due to an interruption in the connection between the battery and the electronics (establish a connection), a faulty main switch (replace the main switch), or a blown additional supply line fuse (replace the supply line fuse).
  • D
    David HarrisAug 26, 2025
    Why does the compressor in my Waeco Refrigerator run constantly?
    • L
      lestergabrielAug 26, 2025
      If the compressor in your Waeco Refrigerator is running constantly, it is likely due to a faulty thermostat. The suggested solution is to change the thermostat.
  • M
    Melody TerrellAug 28, 2025
    How to prevent overheating of the electronics unit in my Waeco Refrigerator?
    • S
      stephaniegordonAug 28, 2025
      To prevent overheating of the electronics unit in your Waeco Refrigerator, avoid heavily loading the cooling system or setting the temperature too high.
  • J
    John GonzalezAug 30, 2025
    Why is the speed too low in my Waeco Refrigerator?
    • M
      Michelle ArellanoAug 31, 2025
      The speed in your Waeco Refrigerator might be too low because the cooling system is overloaded, preventing the motor from maintaining its minimum speed of 1850 RPM.
  • M
    Melissa HamiltonSep 2, 2025
    Why Waeco CoolMatic CD50 is not working because of the supply voltage?
    • J
      Jacqueline WardSep 2, 2025
      Your Waeco Refrigerator might not be working if the supply voltage is outside of the set range.
  • M
    Melanie BlackSep 4, 2025
    What causes excessive fan current in a Waeco CoolMatic CD50 Refrigerator?
    • P
      Paul ElliottSep 4, 2025
      Excessive fan current in a Waeco Refrigerator occurs when the fan loads the electronics unit with more than 1 A.
  • D
    Daniel RossSep 6, 2025
    What to do if the electric circuit between the pins in the compressor is interrupted in Waeco Refrigerator?
    • R
      robert44Sep 6, 2025
      If the electric circuit between the pins in the compressor is interrupted, it indicates a defective compressor. This issue can only be repaired by an authorized customer services unit.
  • L
    Lucas LloydSep 8, 2025
    What to do if my Waeco CoolMatic CD50 compressor does not run and it's related to the battery?
    • A
      angelabrownSep 9, 2025
      If your Waeco Refrigerator compressor isn't running and you suspect a battery connection issue, several factors could be at play. There might be an interruption in the connection between the battery and the electronics, so you should establish a secure connection. If installed, the main switch could be faulty and needs replacement. Also, check if the additional supply line fuse has blown and replace it if necessary. The battery voltage might be too low, requiring a charge. Loose cables or poor contact due to corrosion can also cause this issue, so ensure all connections are clean and tight. In some cases, the battery capacity might be insufficient, necessitating a replacement. Finally, ensure the cable cross-section is adequate; if it's too small, replace the cable.

Summary

Explanation of symbols

Safety instructions

General safety

General safety guidelines for the refrigerator, including warnings and precautions.

Operating the device safely

Instructions on safe operation, electrical connections, and usage precautions.

Scope of delivery

Accessories

Intended use

Technical description

Overview

Overview of refrigerator components and features illustrated in figures.

Control elements

Description of refrigerator control elements, including LEDs and buttons, and their functions.

Installing and connecting the refrigerator

Installing the refrigerator

Details installation process: mounting, ventilation, and condensation drainage.

Connecting the refrigerator

Covers DC/AC power connection, wiring, and fuses.

Using the refrigerator

Energy saving tips

Advice on efficient refrigerator usage and energy saving.

Using the refrigerator

Explains operation, temperature setting, and food storage.

Undo the lock

Instructions for operating the refrigerator's locking mechanism for drawers.

Switching off and storing the refrigerator

Guidance on proper shutdown and long-term storage of the refrigerator.

Cleaning and care

Guarantee

Disposal

Troubleshooting

Technical data

Waeco CoolMatic CD50 Specifications

General IconGeneral
Capacity50 liters
Gross Capacity50 liters
Freezer CompartmentNo
Average Power Consumption45 W
SystemCompressor cooling system
RefrigerantR134a
Voltage12/24 V DC
Dimensions (W x H x D)540 x 570 x 450 mm
Dimensions (H x W x D)65 x 55 x 89 cm
InsulationPolyurethane foam