Disposal PerfectPower
26
12 Disposal
➤ Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
13 Technical data
The following technical data applies to all inverters:
PP152,
PP402,
PP602
PP154,
PP404,
PP604
Output voltage
210 – 230 V AC
Output frequency
50 Hz ± 2 Hz
Idle current consumption
< 0.25 A < 0.25 A
Rated input voltage
12 V DC g 24 V DC g
Low voltage alarm
10.8 V 21.5 V
Low voltage cut-off
10 V 20 V
Overvoltage circuit breaker
15.3 V 30.5 V
Heat dissipation
Housing/fan
Maximum ambient temperature
0 °C – 50 °C
Testing/certification
24