7
English
Cleanup
English
Before you begin:
When cleaning, use the appropriate
cleaning solution (warm, soapy water for
latex materials; mineral spirits for oil-based
materials)
Special cleanup instructions for
use with flammable solvents
(must have a flashpoint above
70ºF (21ºC):
• Always ush spray gun outside.
• Area must be free of ammable vapors.
• Cleaning area must be well-ventilated.
• Do not submerge turbine!
1. Turn the turbine OFF.
Trigger the spray gun so
that the material inside
the spray gun ows
back into the container.
2. Unscrew the container.
Empty any remaining
material back into the
material container.
4. Attach the cup to the
gun and turn on the
turbine.
3. Pour a small amount of
the appropriate cleaning
solution into the cup.
Clean cup and suction
tube and properly dispose
of cleaning solution. Rell
the cup with NEW cleaning
solution.
5. Spray the solution through the gun
for two seconds in a safe area.
Spray again for two seconds. Turn
off the turbine, and trigger the spray
gun so that the material inside
the spray gun ows back into the
container. Wipe the exterior of the
cup and gun until clean.
7. Clean the container, suction tube,
air cap and nozzle with a cleaning
brush and the appropriate
cleaning solution.
IMPORTANT: Never clean nozzle
or air holes in the spray gun with
sharp metal objects. Do not use
solvents or lubricants containing
silicone.
6. Unscrew the nut and
remove the air cap and
nozzle.
8. Push the tab below
the trigger, twist and
separate the spray gun
from the handle.
9. Clean the rear of the spray
gun (a) with the appropriate
cleaning solution. Use a
thin layer of petroleum jelly
to lubricate the O-ring (b).
Reassemble spray gun.
1 2 43
5 76 8