Troubleshooting
English
8
Maintenance
Before you begin:
You should inspect the air lters in the turbine
to see if they are excessively dirty. If they are
dirty, follow these steps to replace them.
IMPORTANT: Never operate your unit
without the air lters. Dirt could be sucked
in and interfere with the function of the
unit.
Problem A: Little or no material flow
Cause Solution
1. Nozzle clogged. Clean.
2. Suction tube clogged. Clean.
3. Material volume setting turned too low (-). Increase volume setting (+).
4. Suction tube loose. Insert.
5. No pressure build up in container. Tighten container.
6. Air lter clogged. Change.
Problem B: Material leaking
Cause Solution
1. Nozzle loose. Tighten.
2. Nozzle worn. Replace.
3. Nozzle seal worn. Replace.
4. Material build-up on air cap and nozzle Clean.
1. Press the tabs (a) on each side of the turbine to
remove the lter covers.
2. Remove the dirty lters from the turbine and
replace with new ones. The smooth side of the
air lter must be placed toward the turbine.
Secure the covers back onto the turbine.
1 2