Example:
Your meter rea-
ding is 13%
(Figure 1). Your
species is Bass-
wood, American.
Locate your species on the tables provided.
Find the species in the appropriate row.
Find the meter reading in the appropriate
column. Where row and column intersect
is the actual reading for Basswood,
American—16.2%.
THE LOW-BATTERY
light will come on when
the battery needs replac-
ing. Replace with either a
9V alkaline battery. Ob-
serve correct polarity.
CALIBRATION is factory set. Factory
calibration can be veried using a
calibration verication block (CVB). The
CVB is for calibration verication only.
Figure 1