Start up
10 0241891 – PI-P1 / PI-F1 08/2008
2.3.2 Powder injector PI-P1
Caution
Deactivate the high voltage!
Proceed as follows:
1. Check that the high voltage has been
deactivated.
2. Connect the feed air and dosage air.
3. Disconnect powder feed hose S, plug-
in nipple F for the feed air and cou-
pling D for the dosage air from the
powder injector.
4. Pull the powder injector out of the in-
jector connection.
5. Blow through the powder injector from
the powder intake A with spurts of
compressed air and clear of all pow-
der residue or deposits.
6. Connect the powder feed hose S,
plug-in nipple F for the feed air and
coupling D for the dosage air to the
powder injector again.
7. Check the grounding before
re-starting.