Turn on the machine and spray the solvent or water into a container or a cloth.7)
Repeat the above procedure until the solvent or water emerging from the nozzle is 8)
clear.
Turn o the machine and divide the spray gun.9)
Screw of the container and empty it. Pull out the suction tub with container seal.
10)
CAUTION! Never clean seals, diaphragm and nozzle or air holes of the spray gun
with metal objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
Pull the ventilating hose (Fig.12 A, 14) at the top from the gun body. Screw o the valve
11)
cover (15). Remove the diaphragm (16). Clean all the parts carefully.
Unscrew the union nut and remove the air cap and nozzle. Clean the air cap, nozzle 12)
seal and nozzle with a brush and solvent or water (Fig. 12, 5).
Clean the outside of the spray gun and container with a cloth soaked in solvent or
13)
water.
Assemble the parts again (see Assembly”).14)
Assembly
The unit may only be operated with an integer diaphragm (Fig. 12 A, 16). Place the
diaphragm with the pin facing upwards on the bottom section of the valve. Also see
the marking on the gun body. Place on the valve cover and screw it closed. Place the
ventilating hose on the valve cover and on the nipple at the gun body.
Slide the nozzle seal (Item 4) with the groove (slot) facing forwards into the nozzle (Fig. 12 B).
Put the nozzle onto the gun body and nd the correct position by turning it. Put the air
cap onto the nozzle and tighten it using the union nut.
Place the container seal from below on the suction tube and slide it over the collar, while
turning the container seal slightly. Insert the suction tube with container seal in the gun
body.
Maintenance
Change the air lter if it is soiled. For this pull the air lter out of the unit (Fig. 11). Insert a
new air lter with the at side at the back (looking towards the unit).
WARNING! Never operate the machine without the air lter; dirt could be sucked in
and interfere with the function of the machine.
In order to mount the gun more easily apply lubricating grease (enclosed) liberally
to the O-ring at the gun front part (Fig. 12, 18).
Spare Parts List (Fig. 12)
Pos. Name Order No.
1 Union nut 0417 319
2 Air cap 2305 129
3 Nozzle (2.5 mm) 2305 131
4 Nozzle seal 0417 706
5 Perfect Spray spray attachment incl. 800 ml. container 0417 914
6 Handle 0414 240