EasyManuals Logo

WAMGROUP SILOTOP R03 Series User Manual

Default Icon
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
SILOTOP R03
3.0 TECHNICAL INFORMATION
2
FIL.100.--.M.EN Issue: A2
06.12
12
3.6 Noise level
The noise level of the SILOTOP
®
R03 series dust collector does not exceed the limit of the directive 86/188/
CEE and 89/392/CEE.
The measured equivalent continuous A-weighted sound pressure level LAeq is 70.0 dB(A).
All readings were taken at 1 metre distance from the equipment at 1.6 metres from ground, with compressed
air shots at 6 bar each 28 seconds, using a precision sound level meter.
Noise measurements of installed equipment may vary due to site conditions.
%BOHFS8BSOJOH
Depending on the installation site, the installer must adopt suitable systems (barriers, etc.), if neces-
VDU\WRPDLQWDLQWKHQRLVHOHYHOVZLWKLQWKHOLPLWVSHUPLWWHGE\ODZ
3.7 Environmental operating limits
8QOHVVRWKHUZLVHVSHFL¿HGWKHHTXLSPHQWFRQFHUQHGPD\EHXVHGRQO\ZLWKLQWKHOLPLWVLQGLFDWHG
- Altitude: less than 1,000 m at sea level
- Environmental temperature: between - 20 °C and + 40 °C
- Cold climates: with temperature less than 5 °C use oil and lubricants suitable to the operating temperature.
Generally protect the equipment appropriately according to the prevailing conditions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAMGROUP SILOTOP R03 Series and is the answer not in the manual?

WAMGROUP SILOTOP R03 Series Specifications

General IconGeneral
BrandWAMGROUP
ModelSILOTOP R03 Series
CategoryDust Collector
LanguageEnglish