7.0 INFORMATION REGARDING MAINTENANCE
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
44
%BOHFS8BSOJOH
Before carrying out any maintenance activity, activate all the safety devices to ensure the safety of the
persons involved in the operations and those near by.
Set the equipment concerned in safety condition (see 2.0 Information regarding safety).
Wear suitable personal protection equipment; in this regard, consult the person in charge of produc-
tion activites safety.
- Scheduled maintenance Table
Component Operation to be carried out Daily
Every
month
Every
six
months
Every
WZR
years
Manual
reference
Safety devices Performance check
Inspection hatches Checking the condition
Flanged assembly Checking the seal
Air tank
Checking the pressure and
condensation
Filter elements
Checking the state of the
¿OWHUPHGLDDQGGLIIHUHQWLDO
pressure
Compressed air Checking value and presence
Control panel Checking the condition
Solenoid valve
Checking the functioning and
condition
Blowing pipes Checking the condition
7.1 Cleaning the equipment (the machine)
Clean the outside part of the equipment (the machine) using a vacuum cleaner to prevent dispersal of dust in
the environment and in the surrounding area; or use a moist cloth.
Do not use compressed air.
Wash the equipment (the machine), after vacuuming the dust, with a low-pressure water jet.