13
Caution – This hot blending lid retains hot liquids after
use. Let cool and handle carefully when disassembling.
MAINTENANCE
Motor – Not for water-jet cleaning.
The Waring Commercial Blender ball-bearing motor requires
no greasing or oiling. Sealed-in lubrication provides smooth
unit operation.
Container – The stainless steel or copolyester container can
be sterilized without injury to the bearing.
Container pad is to be washed and rinsed in solutions as
noted in the Cleaning and Sanitizing Instructions.
Depending on the operating conditions, service life of the
main components of the container blade assembly, socket
head shaft and shaft seals is 500 hours of actual running time.
When any one of these main components has worn to the
extent that replacement is required, it is likely that the other
components will need to be replaced also. It is therefore
recommended that container blade assemblies be replaced
as a unit.
Die-cast lock nut must be tightened securely (65 to 70 foot-
pounds torque) when reassembling container.