Safety Warnings

Initial Checks and Claims Procedure

Check unit condition upon receipt and report issues within 48 hours for claims.

Professional Installation and Service

Installation must be by qualified personnel to avoid warranty loss or damage.

General Information

Technical Specifications

Installation and Connections

Electrical Connection

Commissioning the Heat Pump

Valve Checks

Verify the status of inlet, outlet, and bypass valves before operation.

Filter Cleaning

Clean the filter weekly to ensure optimal functioning of the unit.

Valve Adjustments

Adjust bypass, inlet, and outlet valves to specific settings for operation.

Heat Pump Operation and Modes

Silent Mode Operation

Decreases compressor speed, potentially affecting performance.

Mode Selection and Settings

Change operating mode and access parameter settings.

On;Off Control

Turn the unit on/off, cancel operations, or return to the last mode.

Navigation Controls

Scroll through operating and temperature parameters using up/down buttons.

Operating Mode Indicators

Displays for cooling, heating, automatic, and defrosting modes.

Error Codes

Error Code E01

HP pressure switch detects high refrigerant pressure. Contact customer service.

Error Code E02

LP pressure switch detects low refrigerant pressure. Contact customer service.

Error Code E03

Faulty flow sensor contact. Check calibration, connections, and clean sensor.

Error Code E04

HP&BP pressure switches detect anomaly due to low refrigerant. Contact after-sales service.

Error Code E08

No connection between control box and heat pump. Check wiring or replace control box.

Error Code P01

Malfunction of water inlet temperature sensor. Check probe, cable, or replace sensor.

Error Code P02

Malfunction of water outlet temperature sensor. Check probe, cable, or replace sensor.

Error Codes P03;P04

Malfunction of ambient air temperature sensor. Check probe, cable, or replace sensor.

Error Code P05

Malfunction of evaporator temperature sensor. Check probe, cable, or replace sensor.

Error Code P06

Significant temp difference or PCB malfunction. Check valves, sensors, flow, or replace PCB.

Error Code P07

Malfunction of suction temperature sensor. Check probe, cable, or install resistor.

Fault Code F

Contact technical service for F-code faults.

Maintenance and Warranty

Evaporator Cleaning

Clean the evaporator fins regularly with a water jet for optimal airflow.

Condensate Outlet Maintenance

Unclog condensate outlets to prevent water accumulation and corrosion.

Winterization Procedures

Mandatory Winter Storage

Winter storage is mandatory at the end of the season to prevent exchanger freezing.

Power and Water Disconnection

Disconnect electrical power and water lines, close valves.

Hydraulic System Preparation

Unscrew connections, empty the hydraulic system, leave space.

Manufacturers Warranty

Safety Tips

Fan Operation Hazard

Do not touch the operating fan to avoid injury. Keep appliance away from children.

Electrical Connection Checks

Regularly check power supply and connection cables for safety.

Use of Original Parts

Use only manufacturer's original parts for after-sales service.