EasyManua.ls Logo

Warmtech WTCAC15-DU - Troubleshooting

Warmtech WTCAC15-DU
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
TROUBLESHOOTING
Before you send out the heater for repair please check the following points first, they are not faults
Problem
reason
Odor, smoke or spark omitted by the first
use
It is normal. Because at the beginning there are air and
dust mixed in the burning. Wait for some time they will
disappear.
Ignite when he first use or when the fuel
was used out, strange sounds, odor, white
smoke
Air is mixed in the pipe,
the phenomenon will disappear
when the air in the pipe was pressed out.
Strange sound while igniting or flameout
The metal parts of the heater expand and contract cause
the noises. normal
Fire appears out of the outlet while igniting.
Sparkle
Fuel and air of last time were left in the oil pipe of the
nozzle, so the air and fuel are not proper mixed, the
burning isn’t continuous. Sparkle is caused by the left
carbon powder, is also normal
trouble shooting guide--reason and solution
trouble
Heater does
not start
Flame does
not
ignite
Flame
goesout
while burning
Fuel leaks
Smoke or
dust
Fire
from
outlet
solution
No power
Make sure
the power is
proper
connected
Power
breakdown
When the
power
recovers,
operate the
heater again
Low voltage
Resolve the
problems
which cause
the voltage
gets low
Frequency not
proper
Use the
defined
frequency on
the label
The air hole
blocked
Clean the
hole on the
fuel tank cap
Filter blocked
Check and
replace the
filter
Fuel
exhausted
Fill the tank
Water is mixed
in the tank
Clean the
fuel tank
The quality of
fuel is bad
Clean the
fuel tanks
and fill fresh
kerosene or
diesel
Fuel drain
screw isn’t
tightened
Tighten the
screw
Others
Contact your
dealer or
service
personnel