13). FAULT-TRACING
Type of fault Corrective action
No arc. Check that the mains power supply
switch is turned on.
Check that the welding current supply
and return cables are
correctly connected.
Check that the correct current value is
set.
The welding current is
interrupted during welding.
Check to see whether the thermal
cut-outs have tripped.
The thermal cut-out trips
frequently.
Make sure that you are not exceeding
the rated data for the
welding power source (i.e. that the
unit is not being
Poor welding performance. Check that the welding current supply
and return cables are
correctly connected.
Check that the correct current value is
set.
Check that the correct electrodes are
being used.
Check the gas flow.
14) ERROR CODES :-
ERROR 001 :-
passing through the torch then the Err 001 will be displayed on the display.
ERROR 002 :-
will be displayed on the display.
15). DISMANTLING AND SCRAPPING
Welding equipment primarily consists of steel, plastic and non-ferrous metals,
and must be handled according to local environmental regulations.