13). FAULT-TRACING
Type of fault Corrective action
No arc. Check that the mains power supply
switch is turned on.
Check that the welding current supply
and return cables are
correctly connected.
Check that the correct current value is
set.
Check
the
mains
power
supply.
The welding current is
interrupted during welding.
Check to see whether the thermal
cut-outs have tripped.
Check
the
mains
power
supply
fuses.
The thermal cut-out trips
frequently.
Make sure that you are not exceeding
the rated data for the
welding power source (i.e. that the
unit is not being
overloaded).
Poor welding performance. Check that the welding current supply
and return cables are
correctly connected.
Check that the correct current value is
set.
Check that the correct electrodes are
being used.
Check the gas flow.
14) ERROR CODES :-
A)
ERROR 001 :-
If
the
water
circulation
pump
is
off
or
the
water
is
not
passing through the torch then the Err 001 will be displayed on the display.
B)
ERROR 002 :-
If
the
welding
machine
is
over
heated
then
the
Err
002
will be displayed on the display.