WATER ACE PUMP COMPANY
|
1101 MYERS PARKWAY
|
ASHLAND, OHIO 44805-1969 (USA ONLY)
CONSUMER HOT-LINE: 1-800-942-3343
Monday–Friday 7 AM to 5 PM EST
www.waterace.com
INSTALLATION MANUAL Pgs. 1–4
SUBMERSIBLE SUMP PUMPS
POMPES DE PUISARD SUBMERSIBLES
MANUEL D’INSTALLATION Pgs. 5–8
MANUAL DE INSTALACIÓN Pgs. 9-13
BOMBAS DE SUMIDERO SUMERGIBLES
23833A115 (1/19/06)
MODEL
R5V
1/2 HP
MODEL
R3S
1/3 HP
MODEL
R3V
1/3 HP
MODEL
R2SA
1/4 HP
MODEL
R5S-1
1/2 HP

Questions and Answers

  • P
    Paul GentryAug 8, 2025
    Why does the fuse blow or circuit breaker trip when my Water Ace R3S Water Pump starts?
    • M
      michael48Aug 8, 2025
      If your Water Ace Water Pump's fuse blows or the circuit breaker trips when the pump starts, it could be due to several reasons. The pump impeller might be partially clogged with tar or paint, causing the motor to run slowly and overload. Alternatively, the fuse or circuit breaker might be too small; it should be 15 amps. Also, check if the impeller or volute openings are clogged and need cleaning.
  • Z
    zachary85Aug 13, 2025
    What to do if my Water Ace R3S Water Pump runs but doesn't pump water?
    • S
      seth60Aug 13, 2025
      If your Water Ace Water Pump runs but does not deliver water, several issues could be the cause. First, ensure the check valve is installed correctly, with the arrow pointing in the direction of flow. Also, check that the discharge shutoff valve is open, if one is being used. The pump might be air-locked; try starting and stopping it several times by plugging and unplugging the cord. Inspect the pump case for a clogged vent hole, and examine the impeller or volute openings, as well as the inlet holes in the pump base, for any clogs that need cleaning. Lastly, consider whether the vertical pumping distance is too high, requiring a reduction in distance or a resizing of the pump.
  • A
    Allison SmithAug 17, 2025
    How to troubleshoot a Water Ace Water Pump that does not run?
    • H
      hdanielsAug 17, 2025
      If your Water Ace Water Pump does not run or hums, there are several potential causes. First, check the line circuit breaker and replace the fuse if necessary. Ensure the water level in the sump has reached the correct turn-on level as indicated in the installation drawing. Verify that the pump cord is making proper contact in the receptacle. Also, make sure the float operates freely in the basin. If all of these are okay, the motor winding may be open.
  • E
    Elizabeth WellsAug 23, 2025
    Why does my Water Ace Water Pump keep running and not stop?
    • D
      Darlene JamesAug 23, 2025
      If your Water Ace Water Pump runs and pumps out the sump but doesn't stop, the float may be stuck in the up position. Ensure the float operates freely in the basin. Also, consider replacing the float switch (RSMA) for R2SA, R3S and R5S-1, or replacing it with a vertical switch RVS for R3V and R5V.
  • S
    Scott BradfordAug 27, 2025
    Why is my Water Ace R3S delivering only a small amount of water?
    • M
      Micheal LongAug 28, 2025
      If your Water Ace Water Pump runs but delivers only a small amount of water, it could be due to the pump being air-locked; try starting and stopping it several times by plugging and unplugging the cord. The vertical pumping distance might be too high, so consider reducing the distance or resizing the pump. Also, check for clogged inlet holes in the pump base, or clogged impeller or volute openings. The pump impeller might also be partially clogged with tar or paint, causing the motor to run slowly and overload; in any of these cases, you should remove the pump and clean it.
  • L
    Lori JeffersonSep 2, 2025
    Why does my Water Ace R3S Water Pump motor run for a short time, then stop?
    • J
      jfrostSep 2, 2025
      If your Water Ace Water Pump motor runs for a short time, then stops, it could be due to several reasons. The inlet holes in the pump base may be clogged, or the pump impeller may be partially clogged with tar or paint, causing the motor to run slowly and overload. Also, the impeller or volute openings might be fully or partially clogged. In any of these cases, remove the pump and clean the openings. Additionally, the motor stator may be defective.

Summary

INSTALLATION MANUAL SUBMERSIBLE SUMP PUMPS

IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Critical safety warnings, electrical precautions, and general guidelines prior to pump installation.

SUBMERSIBLE SUMP PUMP INSTALLATION

Step-by-step guide and necessary materials for correctly installing the sump pump.

PIPING

Details on using PVC pipe, fittings, and a check valve for the pump's discharge system.

TROUBLESHOOTING CHECKLIST

LIMITED WARRANTY

Water Ace R3S Specifications

General IconGeneral
BrandWater Ace
ModelR3S
CategoryWater Pump
LanguageEnglish