8
Main Menu
12:00
1. To enter Main Menu, press the Menu/Enter button.
(Time of Day will ash)
2. To set the Time of Day, press the Set/Change button.
(First digit will ash) Example (12:00)
To change digit value, press the Set/Change button.
- To accept the digit value, press the Menu/Enter button.
- Next digit will ash to begin setting.
- Once the last digit display is accepted, all digits will ash.
3. To set A.M. or P. M ., press the Menu/Enter button.
- To change digit value, press the Set/Change button. Example ( A )
- To accept the digit value, press the Menu/Enter button.
- Once A.M. or P.M. is accepted, the next menu item will ash.
4. a. To set the Number of Days between Backwash Cycles (A), press the Set/Change button.
Repeat instructions from step (2). Example ( A - 06 )
1) Maximum value is 29.
2) If value set to 0, Automatic Backwash will never occur.
3) Default setting is 6 days for lters.
- Final Checkout -
1. Be certain that the bypass valve is in Service position and main valve is completely on.
2. Check electrical supply to be certain the cord is connected to an uninterrupted 115 volt outlet.
3. REGISTER YOUR PRODUCT at www.watersoftinc.com
4. Leave this manual with the homeowner.
Important Notice - The plumbing system, piping, pressure tank, hot water tanks, softeners, etc. that have
been exposed to iron bearing water may need to be cleaned of the precipitated iron that has been collected
in them or iron bleed thru may be a problem. We suggest all tanks be drained and ushed thoroughly.
- Programming The Control Valve -
1. Set time of day.
2. Set a.m. or p.m.
3. Set number of days between backwash. (This generally will be every 4 to 6 days.)
1. Set regeneration time if other than 12:00 a.m. is desired.
Programming the Control Valve
Warning: Close handle on bypass prior to selecting the backwash position. After backwash position has
been established, slightly open valve on bypass to evacuate air from the media tank. Fully open
bypass valve when all air is depleted. This procedure will prevent media form being uplifted into
control valve.
2. Advance control valve to RAPID RINSE (cycle 3) position and allow water to run to drain for 3 to 4 min
utes.
3. Advance control valve to SERVICE (cycle 0) position.