Page 1
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
5 SV DELUXE
WATTS PREMIER 25
CRO-TFM-5SV
ULTRA 5
RO-TFM-4SV
RO-TFM-5SV
PUR-TEK
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier, Inc. 1725 W. Williams Drive C-20 Phoenix, AZ 85027
Phone: 800-752-5582 www.wattspremier.com Fax: 623-931-0191
Save manual for future reference
MODELS
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the product’s failure and possible damage to property.
System Tested and certified by NSF International against ANSI/NSF
Standard 58 for the reduction of claims specified on performance data sheet.

Questions and Answers

  • D
    Dawn WilliamsAug 4, 2025
    What to do if Watts Premier Water System filter housing leaks?
    • M
      Mrs. Kelly FischerAug 4, 2025
      If water leaks from the blue/white filter housing: * Ensure the bowl is properly tightened. * If there is a kinked o-ring: Turn off the water supply and release the pressure. Replace the o-ring if necessary. Lubricate it and make sure it is seated properly in the filter bowl before reinstalling.
  • S
    Shari GlassAug 8, 2025
    Why is my Watts Premier Water System producing water slowly?
    • C
      Caitlin GreenAug 8, 2025
      Several factors can cause low or slow water production. Check the following: * Ensure incoming water pressure is at least 40 psi. If it's too low, Watts Premier sells a booster pump. * Confirm the water supply is on and the Adapta Valve is fully open. * Inspect tubing for crimps and straighten or repair them. * Replace clogged pre-filters. * Replace the membrane and Flow Restrictor if the membrane is fouled.
  • S
    shirley92Aug 12, 2025
    What to do if Watts Premier Water System constantly running and won't shut off?
    • J
      Jeffery GrantAug 12, 2025
      If your system won't shut off, there are several potential causes: * Low water pressure: Ensure a minimum of 40 psi incoming water pressure. * Crimp in supply tube: Inspect the tubing and straighten or repair as necessary. * High water pressure: Verify that the incoming water pressure does not exceed 80 psi. A pressure relief valve may be required. * High pressure in: Empty the storage tank of water and set the tank air pressure to 5 psi.
  • C
    Christina MillerAug 16, 2025
    Why does my Watts Premier Water System faucet leak from the airgap feature?
    • X
      Xavier LewisAug 16, 2025
      Airgap faucet leaks can occur due to: * A crimp in the drain line: Check the tubing. * A restriction in the drain line: Straighten all drain lines, clear any blockages, and cut off any excess tubing. * A clogged drain tube: This is often caused by the dishwasher or garbage disposal. Disconnect the 3/8" black line at the drain, clean it out with a wire, and then reconnect it. Blowing air through the line may not always remove the clog.
  • S
    Sarah StevensAug 21, 2025
    Why is my Watts Premier Water System making noise from the faucet or drain?
    • C
      Courtney BonillaAug 21, 2025
      Noise issues can stem from a few sources: * Air gap faucet: The sound is inherent with air-gap faucets. * Location of drain saddle: Check the diagram for proper location of the drain saddle. * Restriction in drain tube: Clear any blockage that may be caused by debris from the garbage disposal or dishwasher. * High water pressure: A pressure regulator is required if the pressure exceeds 80 psi.
  • J
    Jeremy HowardAug 25, 2025
    Why is there a small amount of water in my Watts Premier Water System storage tank?
    • R
      rchenAug 26, 2025
      A small amount of water in the storage tank could be due to: * System just starting up: It normally takes 6-10 hours to fill the tank. Low pressure and/or temperature can drastically reduce production rate. * Low water pressure. * Excessive air in the tank bladder: Tank pressure is set at the factory and should be 5 psi when empty. Add air if below 5 psi and bleed air if above 5 psi. Check only when the tank is empty.
  • A
    Amanda TurnerAug 29, 2025
    Why is the water from my Watts Premier Water System milky colored?
    • H
      hawkinsrandallAug 29, 2025
      Milky colored water is often due to air in the system. This is normal when initially starting up the RO system and should disappear within 1-2 weeks of normal use. If it reoccurs after filter changes, drain the tank 1 to 2 times.

Summary

Operational Parameters

Tools Recommended for Installation

Faucet Installation Guide

Drill a Hole for the Faucet in a Porcelain Sink

Detailed instructions for drilling a faucet hole in a porcelain sink.

Punch a Hole for the Faucet in a Stainless Steel Sink

Procedure for creating a faucet opening in a stainless steel sink.

Wave Faucet Installation

Steps for installing the Wave Air Gap or non-air gap faucet.

AG-SS with Monitor Faucet Installation

Guide for installing the AG-SS model with monitor faucet.

Plumbing and Module Installation

Adapta Valve Installation

Instructions for connecting the Adapta Valve to the water supply.

Reverse Osmosis Module Mounting

Guidance on securely mounting the RO module within a cabinet.

Drain Saddle Installation

Steps for installing the drain saddle onto the sink's drain pipe.

Tank Tee Installation

Procedure for attaching the tank tee to the system's storage tank.

Tube and Filter Connections

Green Tube Connection

Connecting the green tube from the RO module to the Adapta Valve.

Blue Tube Connection

Connecting the blue tube from the RO module to the storage tank.

Black Tube Connection

Connecting the black tube from the faucet to the drain saddle.

Red Tube Connection

Connecting the red tube from the faucet to the RO membrane housing.

6 Final Filter Installation

Steps for installing the 6-inch final filter unit.

10 Final Filter Installation

Instructions for installing the 10-inch final filter.

System Operation and Maintenance

Start up Instructions

Guide for initial system setup and activation after installation.

6 Month System Maintenance

Procedures for performing semi-annual system maintenance.

Annual Maintenance

Steps for annual system upkeep and sanitization.

Membrane Maintenance

Detailed guide for replacing the RO membrane.

Check Air Pressure in the Tank

How to check and adjust air pressure in the storage tank.

Troubleshooting Guide

Low;Slow Production

Addresses issues with low or slow water output from the system.

Milky Colored Water

Explains the cause and solution for milky or cloudy water.

Water Constantly Running; Unit Will Not Shut Off

Troubleshoots situations where the system fails to stop running.

Noise from Faucet or Drain

Identifies sources of noise from the faucet or drain connection.

Faucet Leaks from the Air Gap Feature

Guides on fixing leaks originating from the faucet's air gap.

Small Amount of Water in Storage Tank

Investigates causes for insufficient water accumulation in the tank.

Water Leaks from the Blue; White Filter Housing

Addresses leaks occurring at the blue or white filter housings.

Watts Premier ULTRA 5 Specifications

General IconGeneral
Product TypeReverse Osmosis System
Stages of Filtration5
Flow Rate50 gallons per day
Installation TypeUnder Sink
NSF CertificationsNSF/ANSI Standard 58
Membrane TypeThin Film Composite (TFC)
Filter TechnologyCarbon Block
Included ComponentsFaucet, Tank, Filters
Filter Life6-12 months (Pre and Post Filters), 2-5 years (Membrane)
Weight25 pounds

Related product manuals