INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier, Inc. 1725 W. Williams Drive C-20 Phoenix, AZ 85027
Phone: 800-752-5582 www.wattspremier.com Fax: 623-931-0191
Save manual for future reference
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the product’s failure and possible damage to property.
Manual Edition: 08/21/07
P/N 199404
Model: RO-PURE
System Tested and certi ed by WQA against NSF/ANSI
Standard 58 for the reduction of the claims speci ed on the
performance data sheet.
Available From:
®
freshwatersystems.com
serving you since 1989
CLICK HERE

Questions and Answers

  • D
    davidhamiltonAug 17, 2025
    Why is Watts Premier Water System leaking water from the filter/membrane housing?
    • M
      monica42Aug 18, 2025
      If water leaks from the filter or membrane housing of your Watts Premier Water System, it might not be properly inserted. Try re-inserting the filter or membrane housing to ensure a secure fit.
  • S
    shannoncobbAug 20, 2025
    What to do if Watts Premier RO-PURE Water Filtration Systems leaks from the filter housing?
    • A
      amypayneAug 20, 2025
      If you find water leaking from the filter or membrane housing of your Watts Premier Water Filtration System, it might not be properly inserted. Try re-inserting the filter or membrane housing to ensure a secure fit.
  • K
    Kimberly MitchellAug 23, 2025
    How to fix low/slow production in Watts Premier Water System?
    • S
      steven14Aug 23, 2025
      If your Watts Premier Water System has low or slow production, it could be due to several reasons. First, ensure you have a minimum of 40 psi incoming water pressure. Watts Premier sells a booster pump if your home water pressure is low. Also, verify that the water supply is turned on and the Adapta Valve is fully open. Other potential causes include crimps in the tubing (check and straighten or replace if necessary), clogged pre-filters (replace them), or a fouled membrane (replace the membrane and flow restrictor).
  • T
    Timothy GallagherAug 26, 2025
    What to do if Watts Premier Water System constantly running and will not shut off?
    • D
      debrachavezAug 26, 2025
      If your Watts Premier Water System is constantly running and won't shut off, it could be due to low water pressure. Refer to troubleshooting step #1 regarding low water pressure. Another possible cause is a crimp in the supply tube; inspect the tubing and straighten or repair it as needed.
  • F
    fcomptonAug 28, 2025
    How to fix low water flow from faucet in Watts Premier Water System?
    • M
      Michael LeonAug 28, 2025
      To address low water flow from the faucet of your Watts Premier Water System, begin by checking the air pressure in the tank. For optimal results, use a digital air gauge. The empty tank pressure should be 5-7 psi. To reset the air pressure: turn off the water supply and drain the tank by opening the faucet. Once the water stops flowing, remove the Schrader valve cover and pump air into the tank until water ceases to flow from the faucet. Release air from the Schrader valve until you reach 5-7 psi. Replace the Schrader valve cover and turn the water back on.
  • M
    Michael SanchezAug 30, 2025
    Why is there noise/water from faucet vent hole or drain line in Watts Premier Water System?
    • D
      Devon MitchellAug 30, 2025
      Noise or water coming from the faucet vent hole or drain line in your Watts Premier Water System can be caused by a crimp or restriction in the drain line. Inspect the tubing and straighten or repair it as necessary. Another cause could be a clogged drain tube. Disconnect the 3/8” black line at the drain, clean it out with a wire, and then reconnect it. Note that blowing air through the line may not always remove the clog.
  • A
    alexandria71Sep 2, 2025
    What to do if there is a small amount of water in storage tank of Watts Premier Water System?
    • S
      Stephanie ParrishSep 2, 2025
      If you notice only a small amount of water in the storage tank of your Watts Premier Water System, it could be due to a few reasons. If the system is starting up, it normally takes 6-10 hours to fill the tank. Note that low incoming water pressure and/or temperature can significantly reduce the production rate. Another potential cause is low water pressure, refer to troubleshooting step #1 regarding low water pressure. Also, check for too much air in the tank. The tank air pressure should be 5 psi when empty of water; add air if below 5 psi or bleed air if above 5 psi. Check only when the tank is empty of water.
  • S
    Sharon WaltersSep 4, 2025
    Why is my Watts Premier RO-PURE Water Filtration Systems producing water so slowly?
    • D
      Donna ElliottSep 4, 2025
      If your Watts Premier Water Filtration System is producing water slowly, it might be due to several reasons. First, ensure that your incoming water pressure is at least 40 psi. If it's lower, Watts Premier sells a booster pump. Also, check that the water supply is fully turned on and the Adapta Valve is completely open. Other potential causes include crimped tubing (check and straighten or replace if needed), clogged pre-filters (replace them), or a fouled membrane (replace both the membrane and the flow restrictor).
  • K
    Katherine HayesSep 7, 2025
    What to do if Watts Premier Water Filtration Systems constantly running and will not shut off?
    • C
      carrollzacharySep 7, 2025
      If your Watts Premier Water Filtration system is constantly running and won't shut off, it could be due to low water pressure. Refer to solution #1 for details on addressing this issue. Another possible cause is a crimp in the supply tube. Inspect the tubing and straighten or repair it as necessary.
  • M
    Miss Laura DeckerSep 9, 2025
    How to stop noise from Watts Premier RO-PURE Water Filtration Systems drain line?
    • J
      jclarkSep 9, 2025
      If you notice noise or water coming from the faucet vent hole, or hear noise in the drain line of your Watts Premier Water Filtration System, it could be due to a crimp or restriction in the tubing. Inspect the tubing and straighten or repair it as needed. Another cause could be a clogged drain tube. To resolve this, disconnect the 3/8” black line at the drain, clean it out with a wire (blowing air through the line might not be effective), and then reconnect it.

Summary

Warranty Registration

Reverse Osmosis System Overview

Operational Parameters and Tools

Operational Parameters

Key operating conditions for the RO system.

Tools Recommended For Installation

List of necessary tools for proper system setup.

Faucet Installation Guide

Drill a Hole for the Faucet in a Porcelain Sink

Step-by-step guide for creating a faucet opening in porcelain.

Punch a Hole for the Faucet in a Stainless Steel Sink

Step-by-step guide for creating a faucet opening in stainless steel.

Faucet Assembly and Battery

Start up Instructions

System Maintenance

6 Month System Maintenance

Routine procedure for replacing filters every six months.

Membrane Replacement

Guidance on when and how to replace the RO membrane.

System Checks and Troubleshooting

Check Air Pressure in the Tank

Procedure for checking and adjusting tank air pressure.

TROUBLE SHOOTING

Common problems and their solutions for the RO system.

Usage Conditions and Performance

GENERAL USE CONDITIONS

Important conditions and requirements for using the RO system.

Limited Warranty

Watts Premier RO-PURE Specifications

General IconGeneral
BrandWatts Premier