EasyManua.ls Logo

Wavecom WISMO Quik Q2406 - Battery Charging Interface; Figure 19: Example of Battery Implementation

Default Icon
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WM_PRJ_Q2400_PTS_005 -007
18th January 2006
Confidential©
All rights reserved
Page: 31 / 51
This document is the sole and exclusive property of WAVECOM. Not to be
distributed or divulged without prior written agreement.
2.4 Battery charging interface
The WISMO Quik Q24x6 sub-series module has a battery charging interface.
The table below summarizes the battery types supported according to the
software version:
Battery types supported versus software version
Battery type OS version
Before X55 X55 and after
Ni-Cd Supported Supported
Ni-Mh Supported Supported
Li-Ion Not Supported Supported
Warning:
Charging a Li-Ion battery with an OS version prior to X55 may cause damage
to the battery.
This circuit uses an interface which consists of a current source inputs (CHG_IN)
where the constant current has to flow in order to charge the battery.
This current value depends on the battery capacity. It is recommended to
provide a current equal to the value of the capacity plus 50 mA. For a 550 mA
battery the current will be 600 mA. The maximum current is 800 mA.
The WISMO Quik Q24x6 sub-series module monitors the battery voltage to
detect the end of the charge.
It also monitors the temperature of the battery (for security reasons) through the
BAT_TEMP pin which has to be connected to a temperature sensor inside the
battery pack (an NTC resistor for instance).
Typical Implementation:
Safet
y
Circuit
NTC
GND
BAT
_
TEMP
+VBATT
R1
C1
VCC
Internal Battery
Impedance
BATTERY
Figure 19: Example of battery implementation

Table of Contents