SPECIFICATIONS
POWER SUPPLY REQUIREMENTS 120 V, 60 Hz
MOTOR Single Phase, Dielectric Oil Filled
HORSEPOWER
1 HP .................... (CDU1000)
3/4 HP ................ (CDU980E)
1/2 HP............ (CDU800SS, CDU800,
............................. SPF50, CDT50)
1/3 HP ........... (CDU790SS, CDU790,
................................SPF33, WST33)
CIRCUIT REQUIREMENTS 15 A (minimum)
DIMENSIONS
11-1/2 in. high x 9-3/4 in. base
ON LEVEL (FACTORY SET) Vertical: Approximately 9 in.
Tether: Approximately 13 in.
OFF LEVEL (FACTORY SET)
Vertical: Approximately 4 in.
Tether: Approximately 7 in.
600002W-001 F 08/20© 2020, WAYNE/Scott Fetzer Company
Submersible Sump Pump
www.waynepumps.com
Intended for Indoor Use Only
Vertical Float Switch
Tether Float Switch
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
Operating Instructions and Parts Manual Sumps
*Images are for illustration purposes only.
Not all models are shown.
CONSTRUCTION
MOTOR HOUSING
Stainless Steel, (CDU1000, CDU980E,
CDU800SS, CDU790SS)
Coated Steel
(
CDU800, CDU790,
SPF33, SPF50, CDT50)
Reinforced Thermoplastic (WST33)
VOLUTE
CDU1000, CDU980E,
CDU800, CDU800SS
CDU790, CDU790SS,
CDT50
Cast Iron
SPF33, SPF50, WST33
Glass Reinforced Thermoplastic
IMPELLER Glass Reinforced Thermoplastic
SHAFT Steel
PERFORMANCE GAL/HR
Model HP
Discharge Head (Lift Distance)
0 ft 5 ft 10 ft 15 ft 20 ft
CDU1000 1 6100 5460 5100 4560 3840
CDU980E 3/4 5490 5076 4600 4100 3500
CDU800SS
CDU800, CDT50
1/2 5100 4500 3840 3060 2040
CDU790SS,
CDU790
1/3 4600 3810 3060 2220 1200
SPF50 1/2 4300 3900 3360 2700 1260
SPF33 1/3 3750 3300 2718 1920 -
WST33 1/3 3000 2610 2130 1404 400
Question and Answer IconNeed help?

Do you have a question about the Wayne CDU800SS and is the answer not in the manual?

Wayne CDU800SS Specifications

General IconGeneral
ModelCDU800SS
CategoryWater Pump
TypeSubmersible
Discharge Size1-1/2 in
Power Cord Length10 ft
Voltage115 V
Phase1
Hertz60 Hz
Housing MaterialStainless Steel
Impeller MaterialThermoplastic
Thermal ProtectionYes
Switch TypeVertical Float

Summary

Submersible Sump Pump Overview

Specifications

Details electrical requirements, dimensions, and operational levels for the sump pump.

Construction Materials

Information on the materials used for motor housing, volute, impeller, and shaft.

Performance Characteristics

Presents pump performance data in gallons per hour at various discharge head heights.

Sump Pump Description and Safety Guidelines

Product Definition and Purpose

Defines sump pumps and their primary application for basement drainage.

Safety Signal Word Interpretation

Explains the significance of safety labels like Danger, Warning, and Caution.

Electrical Safety and Grounding

Critical instructions on proper electrical connections, grounding, and circuit protection.

Crucial Safety and Installation Directives

Operational Safety Warnings

Covers safe handling, avoidance of electrical shock, and prohibition of hazardous fluids.

Installation Requirements

Mandates rigid piping, check valves, and advises against installing damaged units.

Usage Restrictions and Maintenance Advice

Prohibited Water Types and Usage

Lists unsuitable liquids and applications, recommends backup systems, and states Prop 65 warning.

Component Maintenance and Warnings

Advises on tether switch replacement and warns against float switch modifications.

Typical Sump Pump Installation Diagram

Visual guide illustrating the components and layout of a standard sump pump setup.

Detailed Sump Pump Installation Steps

Pre-Installation and Basin Preparation

Covers code compliance, basin selection, cleaning, and pump placement for optimal switch function.

Plumbing and Electrical Connections

Guidance on installing discharge piping, check valves, and secure electrical hookup.

Post-Installation Testing and Verification

Steps for filling the basin, confirming switch operation, and checking discharge flow.

Troubleshooting and Maintenance Precautions

Essential Troubleshooting Safety

Mandates power disconnection and pump cooling before any servicing or adjustments.

Common Pump Malfunctions and Solutions

Addresses issues like failure to start, short cycling, and independent shut-offs with causes and remedies.

Advanced Troubleshooting and Routine Care

Troubleshooting Specific Operational Issues

Details solutions for GFCI trips, noisy operation, improper shut-offs, and low water delivery.

Routine Pump Maintenance Procedures

Outlines regular inspections, cleaning, testing, and tether switch replacement for longevity.

Parts, Diagrams, and Repair Kits

Pump Component Identification

Provides visual diagrams of the sump pumps for component identification.

Available Repair Kit Part Numbers

Lists the specific part numbers for float kits and tether switches.

Customer Support and Warranty Information

Contacting Wayne for Support and Parts

Provides contact details and required information for customer support and parts orders.

Understanding the Limited Warranty

Explains warranty periods, coverage, exclusions, and the process for making a claim.

Related product manuals