620003-001 B 08/18© 2018, WAYNE/Scott Fetzer Company.
Self-Priming* Portable Multi-Use Pump
www.waynepumps.com
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
Operating Instructions and Parts Manual PC4
SPECIFICATIONS
POWER SUPPLY REQUIREMENTS 120 V, 60 Hz
MOTOR Brush Type
HORSEPOWER 1/2 HP
CIRCUIT REQUIREMENT 15 A (minimum)
LIQUID TEMPERATURE RANGE 40° F- 120° F
CONSTRUCTION
MOTOR HOUSING Cast Iron
MOTOR SHAFT Stainless Steel
IMPELLER Thermoplastic
VOLUTE Cast Iron
PUMP SUCTION 3/4 in. Brass Hose Fittings
PUMP DISCHARGE 3/4 in. Brass Hose Fittings
PERFORMANCE
Model HP
Discharge Head
10 ft. 20 ft. 40 ft. 60 ft. 80 ft.
PC4 1/2 Gal/hr 1600 1500 1240 950 660

Other manuals for Wayne PC4

Question and Answer IconNeed help?

Do you have a question about the Wayne PC4 and is the answer not in the manual?

Wayne PC4 Specifications

General IconGeneral
ModelPC4
Power SourceElectric
MaterialCast Iron
Weight21 lb
Discharge pipe size1.5 inches
Outlet Size1.5 inches
Max Flow Rate42 GPM
Maximum flow rate42 GPM

Summary

Pump Specifications

Pump Construction

Pump Performance

Product Description

Safety Signal Words

General Safety Information

Pump Installation

Maintenance

Brush Replacement

Procedure for replacing worn brushes in the pump motor after 100 hours of operation.

Pump Operation

Service Part Replacement

Replacement Parts and Support