78
Part No. 917543 Rev. A November 1992
06 fault code.
Computer sensed
a valve or relay on
when it should not
be.
Check the solenoid
drive board for 110VAC
output to a valve or
relay.
Is 110VAC
present?
Replace solenoid
drive board.
Replace computer.
Is the
problem
corrected?
Replace computer.
END
YES
NO
NO
YES
JDB-FH-140-A
FLOWCHART A-6. 06 FAULT CODE