Intelligent Fast-Charging System
GSE O&M for DVS300 / 330 / 330 IP55 / 400 and MVS330/400
31504-03-0101 Webasto Charging Systems, Inc.37
Fault or
Warning
Code
Fault or Warning Message Description
Action
Code
116 PS2 General Failure
Power stage #2 (port B) has a current
sensor fault.
W
117 PS2 Overtemp Failure
Power stage #2 (port B) temperature is
too high.
Y
118 DCBus VDC Too Low The common DC bus voltage is too low. X
119 DCBus VDC Too High The common DC bus voltage is too high. X
120 Nt Flt-lost Port X/Lost Main
Network Fault
Lost Port X / Lost Main
GG
121 Network Cfg Failure
The Charger has invalid network Congura-
tion.
GG
126 Temp Sensor Failure The temperature sensor reading is invalid. NN
129 Power Imbalance
There is a power stage power imbalance in
500-A mode.
JJ
132 Invalid Pilot on Port A
The battery is connected with an invalid
pilot circuit.
MM
133 Chrg VDC Port A Low
The battery voltage is too low for the charger
(power station).
Z
134 Chrg VDC Port A High
The battery voltage is too high for the charger
(power station).
Z
135 BMID A Vbat Too Low The battery voltage is too low for the BMID. L
136 BMID VDC Too High The battery voltage is too high for the BMID. L