EasyManua.ls Logo

Webasto Thermo Top T - User Manual

Webasto Thermo Top T
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Ident-Nr. 9000825A 3/0008
Operating Instructions
Telestart T70
Thermo Top and Thermo Top T
Tele Thermo Top T
General Information
Maintenance and Safety Information
Dear Webasto Customer !
We assume that the workshop / service center that carried out the installion explained to
you the operation and principle of functioning of your new heater to your complete
satisfaction. With these operating instructions we would like to provide you with an
overview of the use of the Thermo Top, Thermo Top T and Tele Thermo Top T heaters as
well as the hand-held transmitter Telestart T70.
Within the scope of the StVZO (Road Traffic Licensing Act) "General Design Approvals"
laid down by the Federal Office for Motor Traffic exist for the water heaters.
The installation of the units must be carried out in accordance with the enclosed
installation instructions. The installation must be checked in accordance with the Legal
Provisions for Installation. For details refer to the installation instructions.
The year of the initial operation must be durably marked on the heater's nameplate by
removing the non-applicable years.
Thermo Top
n
n
n
at filling stations and tank farms.
in locations where flammable vapours or dust may
accumulate (e.g. in the vicinity of fuel-, coal-, sawdust or
grain depots).
in enclosed spaces (e.g. garages). This should also be
considered when pre-setting heater operating times or
using the Telestart remote control.
n
n
exposed to temperatures greater than 120°C (storage
temperature). Exposure to such temperatures may cause
damage to the electronic components.
operated without a minimum level of 20% of good quality
antifreeze in the water of the heating circuit.
The heater must be switched :off
Danger of explosions
and asphyxiation
The heater must benot
D
!
Troubleshooting
Fault lock-out deactivation
In the event of a malfunction, fuses and electrical connections should be checked for
condition and security.
In the event of a malfunction, the heater will shut down in its "fault lock-out" mode, no
visual indication will occur on the display of the timer.
Before consulting an authorised Webasto dealer, try to deactivate the fault lock-out
condition.
The following malfunctions can be eliminated by the owner:
B
Z
T
G108
T6
480D
FW
1
2
3
SET
15
A
1
A
25
A
15
A
1
A
25
A
15
A
1
A
25
A
15
A
1
A
25
A
Fault description Possible cause Remedy
Heater turns itself off
automatically
(= fault lock-out)
Combustion is neither esta-
blished during the start-up
sequence nor during the
repeated start-up; flame
extinguishes during operation
Heater fails to turn on No power is supplied
to heater
Check power supply to heater
as well as earthing terminals
Turn off heater and then back
on again (max. 2 times)
Heater turns off during
heating operation
(= fault lock-out
Heater overheats due to
lack of coolantl
Top up coolant in accordance
with manufacturer's directions
If this action does not correct the malfunction, consult your authorised Webasto dealer
Note:
The heater will start operating as soon as the fuse is replaced!
!
Interrupt voltage
supply by removing
the 15A fuse (blue)
in the heater wiring
harness
Interrupt voltage
supply by
removing the 15A
fuse (blue) in the
heater wiring
harness
Reinstallation of
fuse
Reinstallation of
fuse.
The heater will
be turned on.
Briefly press the ON
button on the left of the
transmitter, or press the
button on the digital
timer.
ON
ON
or
wait
ca.
3 sec.
wait
ca.
3 sec.
wait
ca.
3 sec.
Webasto Thermosysteme International GmbH
Postfach 80 - D-82132 Stockdorf - Hotline (01805) 93 22 78
Hotfax (0395) 55 92-353 - http://www.webasto.de

Other manuals for Webasto Thermo Top T

Questions and Answers

  • C
    christina98Aug 11, 2025
    Why does my Webasto Water Heater operate for only a few minutes?
    • L
      Linda WilliamsAug 11, 2025
      If your Webasto Water Heater operates only for a few minutes, consider these potential causes: * The heater might not be seated properly in its support, causing exhaust gas to be aspirated. Loosen the 2 M6 screws and position it correctly. * The fuel lines of the heater might not be properly connected, with flow and return pipes interchanged. Connect the fuel lines in accordance with the installation instructions. * A kinked coolant hose or a cooling system that hasn't been bled completely. Check the line routing and bleed the cooling system, starting the engine.
  • L
    Lindsey WheelerAug 16, 2025
    What to do if Webasto Water Heater fails to ignite but the fan motor is operating?
    • L
      Laura MoraAug 16, 2025
      If your Webasto Water Heater fan motor is operating but the heater fails to ignite, the intermediate fuel reservoir may be empty. Allow the vehicle engine to run for approximately 30 seconds.
  • J
    Jon SmithAug 21, 2025
    What to do if vehicle fan fails to switch on in Webasto Water Heater?
    • A
      Amanda SnowAug 21, 2025
      If the vehicle fan fails to switch on when the threshold temperature (>30° of coolant) is reached in your Webasto Water Heater, a defective fuse F3 could be the cause. Replace the fuse.
  • T
    Tracy CervantesAug 27, 2025
    What to do if Webasto Thermo Top T Water Heater emits blue smoke or soot?
    • R
      Richard StewartAug 27, 2025
      If you notice blue smoke or soot in the exhaust gas, or if the Webasto Water Heater is emitting smoke, it could be due to: * A kinked or blocked suction or exhaust gas line. Check the lines for unobstructed passage. * An installation fault, where the heater is not properly seated in its support, or the gasket of the exhaust gas pipe was not installed. Check the installation.
  • J
    Jenna MurphyAug 31, 2025
    Why is my Webasto Water Heater heat output insufficient?
    • M
      Miss Karla BriggsAug 31, 2025
      If your Webasto Water Heater isn't providing enough heat, make sure the heater control lever is set to 'warm' and the fan switch is set to a higher setting. The heater control lever or vehicle fan may be incorrectly set.
  • S
    Susan TaylorNov 5, 2025
    How to troubleshoot Webasto Thermo Top T Water Heater that can't be switched on?
    • D
      Dr. Eric MarshallNov 5, 2025
      If your Webasto Water Heater won't switch on, several issues could be the cause. It might be in overheating lock-out mode, in which case you should remove the 15A fuse and determine the cause. Check that the summer/winter switch is in the correct position and that the battery isn't discharged (charge it if it is). A defective fuse could also be the reason, so replace it if necessary. If it's a defective digital timer, use a testing device on the heater to check if the digital timer switches properly. Disconnect connector X14 from the heater, connect the testing device, and switch on the digital timer. The indicator lamp must light up; if not, the timer is defective and the power supply to the timer is disrupted. Alternatively, check if 12 V voltage is present across contact 1 (6-pole conne...

Summary

Troubleshooting and Fault Rectification

Troubleshooting Common Faults

Summarizes common malfunctions, their possible causes, and remedies that owners can perform.

Deactivating Fault Lock-Out

Explains the procedure to reset the heater after it has shut down in 'fault lock-out' mode.

General Information and Safety Precautions

General Information

Provides an overview of the heater and its operation, aimed at the end-user.

Maintenance and Safety Information

Covers installation compliance, operational restrictions, and safety warnings.

Heater Operation Restrictions

Details critical situations and environments where the heater must not be operated.

Heater Operational Requirements

Outlines mandatory practices for operating the heater, including fuel, checks, and monthly run times.

Liability Claims

States Webasto's liability limitations concerning installation and repair procedures.

Heater Operation and Control Systems

Heater Operation Guidance

Provides instructions on setting vehicle fan speeds and recommended operating times.

Telestart T70 Overview

Introduces the wireless Telestart T70 remote control for Webasto heating units.

Telestart T70 General Usage

Explains the general usage, range, and essential distance requirements for the Telestart T70.

Programming Telestart Transmitters

Provides a step-by-step guide for programming the Telestart T70 transmitter to the heater.

Checking and Setting Telestart Mode

Details how to check the current operating mode and switch between heating and ventilation.

Timer and Transmitter Control Functions

Manual Switch On;Off

Explains how to manually switch the heater or fan on/off using the transmitter or timer.

Operating Time Settings

Covers how to check and set the operating time for the heater or vehicle fan.

Digital Timer Functions

Explains the digital timer's functions: setting time, programming start times, and erasing programs.

Webasto Thermo Top T Specifications

General IconGeneral
BrandWebasto
ModelThermo Top T
CategoryWater Heater
LanguageEnglish

Related product manuals